HP 7500 Switch Series - 7500-CMW520-F6705L01 Release Notes

8
Condition: Reboot an IRF fabric comprised of four switches. If the switches are not synchronously
rebooted.
Workaround: Make sure the switches have similar card configurations, can back up each other,
and are rebooted at the same time. If the IRF fabric splits, reboot the smallest IRF system so the
switches can join the system to re-form a 4-chassis fabric.
LSD62272
Symptom: RRPP fails to operate.
Condition: If the RRPP control VLAN ID is identical with the subinterface VLAN ID.
Workaround: Do not configure the same VLAN ID for them.
LSD62435
Symptom: A subinterface fails to forward traffic to another chassis.
Condition: If the VLAN ID of subinterface is identical with the MAD VLAN ID.
Workaround: Do not configure the same VLAN ID for them.
List of resolved problems
Resolved problems in F6705L01
LSD68133
Symptom: In this version of code, the password encryption within configuration files has been
enhanced and cannot be interpreted by earlier revisions of the agent code. More details please
reference HP 7500-CMW520-F6705L01 Release Notes (Software Feature Changes).
Condition: If a unit is downgraded to earlier code, it may no longer be possible to login and
manage the device.
LSD072568
Symptom: If an LPU is rebooted when the switch works in IRF mode and uses the SRPA MPU, the
LPU might fail to start up.
Condition: This symptom might occur when the switch works in IRF mode and uses
the SRPA MPU.
LSD072579
Symptom: An SA card on a 7502 fails to forward packets.
Condition: This symptom might occur when the 7502 has an SA card and an SC card.
Resolved problems in R6703
LSD070876
Symptom: The DHCP server supports a maximum of 128 static IP bindings while some scenarios
need more static IP bindings. The maximum number should be changed to 1000.
Condition: This issue exists on the DHCP server.