17
LSD59694
First found-in version: CMW520- R6626
Description: The calculated Q-Bridge MIB port list is incorrect.
Workaround: None
LSD59757
First found-in version: CMW520- R6626
Description: When the user parameter information from the RADIUS server contains a 63-byte
callback-number, a memory error occurs, and the link card fails.
Workaround: Do not configure long callback numbers.
LSD61343
First found-in version: CMW520- R6626
Description: After a user passes HWTACACS authentication, the device receives an authorization
failure packet. Repeated memory releases occur.
Workaround: Do not use HWTACACS authentication.
List of resolved problems
Resolved problems in R6626P02
LSD66072
First found-in version: CMW520-R6626
Description: Non-compatible transceiver module will be invalidated in 30 days.
Workaround: Use compatible transceiver module.
Resolved problems in R6626
LSD62272
First found-in version: CMW520-R6616P05
Description: RRPP fails to operate when the RRPP control VLAN ID is identical with the subinterface
VLAN ID.
Workaround: Do not configure the same VLAN ID for them.
LSD62435
First found-in version: CMW520-R6616P05
Description: A subinterface fails to forward traffic to another chassis when its VLAN ID is identical
with the MAD VLAN ID.
Workaround: Do not configure the same VLAN ID for them.