HP 7500 Switch Series - HP A7500-CMW520-R6635 Release Notes
HP A7500-CMW520-R6635 Release Notes
Hewlett-Packard Development Company, L.P.
29
Card type
Default patch file name
LPU
patch_lpu.bin
Auxiliary CPU on a LPU
patch_lpo.bin
Upgrading an IRF fabric
Upgrade prerequisites
# Telnet to the switch or log in through the console port.
# Display device information.
<Sysname> display device
Chassis Slot Type State Subslot Soft Ver Patch Ver
1 0 LSQ1SRP1CB Master 0 A7500 None
1 1 LSQ1SRP1CB Slave 0 A7500 None
1 2 LSQ1TGX4SD Normal 0 A7500 None
1 3 LSQ1TGX4SD Normal 0 A7500 None
1 4 LSQ1TGX4SD Normal 0 A7500 None
2 0 LSQ1SRP1CB Slave 0 A7500 None
2 1 LSQ1SRP1CB Slave 0 A7500 None
2 2 LSQ1TGX4SD Normal 0 A7500 None
2 3 LSQ1TGX4SD Normal 0 A7500 None
2 4 LSQ1TGX4SD Normal 0 A7500 None
The output shows that two switches form an IRF fabric. The following table shows the MPU information.
Table 11 MPU information of the IRF fabric
MPU
Member ID
Slot number
Active MPU of the IRF fabric
1
0
Standby MPU of the IRF fabric
1
1
Standby MPU of the IRF fabric
2
0
Standby MPU of the IRF fabric
2
1
# Check the free storage space of the active and standby MPUs on the IRF fabric.
On the active MPU of the IRF fabric
<Sysname> dir
Directory of flash:/
0 -rw- 3597 Sep 01 2009 18:35:28 startup.cfg
1 -rw- 6625 Jun 02 2010 16:50:51 switch.cfg
2 -rw- 27475851 Aug 11 2010 11:04:20 switch001.app
3 -rw- 31782388 Jul 23 2010 09:25:21 switch002.app
64389 KB total (5636 KB free)
On the standby MPU in slot 1 of member device 1
<Sysname> dir chassis1#slot1#flash:/