HP FlexFabric 12900 Switch Series - 12900_7.1.R1106-B_Release-Notes-Portfolio

19
Field
Description
FTP User Password
Set the password for accessing the FTP server. This password must
be the same as the one configured on the FTP server.
After you finish setting FTP parameters, the system returns to the Ethernet submenu.
==========================<Enter Ethernet SubMenu>==========================
|Note:the operating device is flash |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
|<Ensure The Parameter Be Modified Before Downloading!> |
============================================================================
Enter your choice(0-4):
7. Enter 2 or 3 as needed. For example, to upgrade the main Comware software images, enter 2.
Loading.....................................................................
............................................................................
.........................Done!
31911744 bytes downloaded!
Image file BOOT.bin is self-decompressing... Saving file
flash:/12900-CMW710-BOOT-R1106.bin ..............................................
Done.
Image file SYSTEM.bin is self-decompressing...Saving file
flash:/12900-CMW710-SYSTEM-R1106.bin .................................. ..Done.
==========================<Enter Ethernet SubMenu>==========================
|Note:the operating device is flash |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
|<Ensure The Parameter Be Modified Before Downloading!> |
============================================================================
Enter your choice(0-4):
8. Enter 0 in the Ethernet submenu to return to the EXTENDED-BOOTWARE menu.
9. Enter 1 in the EXTENDED-BOOTWARE menu to run the new Comware software.
Using Xmodem to upgrade through the console port
1. Connect the console port of the switch to the PC that stores the .ipe file.
2. Run the terminal emulation program on the PC.
3. Start the switch and access the EXTENDED-BOOTWARE menu (see "Using BootWare menus").
4. Enter 2 in the EXTENDED-BOOTWARE menu to access the Serial submenu.
===========================<Enter Serial SubMenu>===========================
|Note:the operating device is flash |