HP FlexFabric 12900 Switch Series - 12900_7.1.R1106-B_Release-Notes-Portfolio
50
If Xmodem is used, verify that the baud rate is the same on the console port and the
HyperTerminal.
If TFTP is used, verify that you entered the correct TFTP server IP address, filename, and file path.
If FTP is used, verify that you entered the correct FTP server IP address, filename, file path, and
FTP username and password.
4. Verify that FTP or TFTP server software is running and has correct settings.
5. Verify that the flash memory is sufficient for storing the downloaded files.
6. Verify that the upgrading file is applicable to the device and the file type is correct.
Verify that the versions of Comware software and BootWare are correct. For the
compatibility between the Comware software and BootWare, see the hardware and software
compatibility matrix in Release Notes.