Release notes - H3C S9500-CMW310-R1652P03

Hangzhou H3C Technologies Co., Ltd.
H3C S9500-CMW310-R1652P03
Release Notes
2010-9-27 Page 35 of 56
6.4 Resolved Problems in S9500-CMW310-R1651P05
1. HYII07675
First Found-in Version: S9500-CMW310-R1651P03
Condition:
The S9500 device needs to support NetStream flow sampling function.
Description:
The current version does not support NetStream flow sampling function.
2. HYII07713
First Found-in Version: S9500-CMW310-R1651P03
Condition:
The S9500 device needs to support L3VPN static route remote-relying.
Description:
The current version does not support L3VPN static route remote-relying.
3. HYII07704
First Found-in Version: S9500-CMW310-R1651P02
Condition:
This problem occurs when the S9500 MPLS LDP was connected with the CISCO
device.
Description:
The LDP cannot be established after receiving LDP TLV message with U-bit flagged.
4. HYII07705
First Found-in Version: S9500-CMW310-R1651P03
Condition:
This problem occurs when the MCX checking is error.
Description:
The MCX checking information printed out wrong on console.