Release Notes - HP A7500-CMW520-R6626
Hewlett-Packard Development Company, L.P. 25
NOTE:
• A patch file must have a valid name. Otherwise, the system cannot identify and install it. Table 9
shows
the default names of patch files.
• For more information about patch installation, see the
Fundamentals Configuration Guide
in the
HP
A7500 Switch Series Configuration Guides
.
Table 10 Patch files for different types of cards
Card type Default patch file name
MPU patch_mpu.bin
LPU patch_lpu.bin
Auxiliary CPU on a LPU patch_lpo.bin
Upgrading an IRF fabric
Upgrade prerequisites
# Telnet to the switch or log in through the console port.
# Display device information.
<Sysname> display device
Chassis Slot Type State Subslot Soft Ver Patch Ver
1 0 LSQ1SRP1CB Master 0 A7500 None
1 1 LSQ1SRP1CB Slave 0 A7500 None
1 2 LSQ1TGX4SD Normal 0 A7500 None
1 3 LSQ1TGX4SD Normal 0 A7500 None
1 4 LSQ1TGX4SD Normal 0 A7500 None
2 0 LSQ1SRP1CB Slave 0 A7500 None
2 1 LSQ1SRP1CB Slave 0 A7500 None
2 2 LSQ1TGX4SD Normal 0 A7500 None
2 3 LSQ1TGX4SD Normal 0 A7500 None
2 4 LSQ1TGX4SD Normal 0 A7500 None
The output shows that two switches form an IRF fabric. The following table shows the MPU information.
Table 11 MPU information of the IRF fabric
MPU
Member ID
Slot number
Active MPU of the IRF fabric 1 0
Standby MPU of the IRF fabric 1 1
Standby MPU of the IRF fabric 2 0
Standby MPU of the IRF fabric 2 1
# Check the free storage space of the active and standby MPUs on the IRF fabric.
• On the active MPU of the IRF fabric
<Sysname> dir
Directory of flash:/