3COM_OS_SW8800_V3.01.32s256rc13_Release_Notes

3COM OS SW8800 V3.01.32s256rc13 Release Notes
April 25, 2013 Page 35 of 56
This will result in OSPF NSSA route surge.
HYII07664
First Found-in Version: V3.01.32s256rc06
Condition:
This problem occurs when the device has IPC (Inter-process Communication) fault.
Description:
The device has no IPC fault checking.
HYII07636
First Found-in Version: V3.01.32s256rc06
Condition:
This problem occurs when we specify the app to boot of board by the command boot-loader.
Description:
It won't perform file-checking when specifying the app to boot of board.
HYII07649
First Found-in Version: V3.01.32s256rc06
Condition:
This problem occurs when the main board has no CF card or the CF card is destructed.
Description:
We cannot collect diagnostic-information for the device.
HYII07645
First Found-in Version: V3.01.32s256rc06
Condition:
This problem occurs when the SW8800 device need configuring the summer-time.
Description:
The summer-time cannot be implemented such as 02:00:00 2009 April fifth Wednesday.
HYII07639
First Found-in Version: V3.01.32s256rc06
Condition:
This problem occurs when to get the hardware version information of board by SNMP.