3COM_OS_SW8800_V3.01.32s256rec13_Release_Notes
3COM OS SW8800 V3.01.32s256rec13 Release Notes
April 25, 2013 Page 46 of 70
This problem occurs when the boards remove from the frame.
Description:
The “VFS RPC SyncCall” information in logfile is some mistake.
HYII07597
First Found-in Version: V3.01.32s256rec05
Condition:
In a network with 3C17526 boards used and STP enabled.
Description:
The CPU sending packets are sent from 3C17526 ports which were blocked by STP.
HYII07605
First Found-in Version: V3.01.32s256rec05
Condition:
This problem occurs when the much multicast packets attack in multicast networking.
Description:
The multicast flow will drop packets when the multicast MAC is added and deleted.
HYII07591
First Found-in Version: V3.01.32s256rec05
Condition:
This problem occurs when the telnet user performed display diagnostic-information.
Description:
The diagnostic information does not include the manufacture information.
HYII07577
First Found-in Version: V3.01.32s256rec05
Condition:
This problem occurs when you display fiber-module information.
Description:
The TX Power of fiber-module information is wrong.
HYII07592
First Found-in Version: V3.01.32s256rec05