3COM_OS_SW8800_V3.01.32s256rec13_Release_Notes

3COM OS SW8800 V3.01.32s256rec13 Release Notes
April 25, 2013 Page 50 of 70
HYII07561
First Found-in Version: V3.01.32s256rec04
Condition:
This problem occurs when the C-type board configures traffic-redirect to the port on same chip.
Description:
The ARP could learn on the wrong port of other board.
HYII07549
First Found-in Version: V3.01.32s256rec04
Condition:
The SW8800 device needs to support the board CPU testing function.
Description:
The current version does not support the board CPU testing function.
HYII07559
First Found-in Version: V3.01.32s256rec04
Condition:
The SW8800 device needs to support the VPLS broadcast local-forwarding.
Description:
The current version does not support the VPLS broadcast local-forwarding.
HYII07540
First Found-in Version: V3.01.32s256rec04
Condition:
This problem occurs when the SW8800 device used some fiber-module whose wavelength is not
850nm, 1310nm and 1550nm.
Description:
The wavelength of fiber-module is UNKNOWN by the display fiber-module command.
HYII07564
First Found-in Version: V3.01.32s256rec04
Condition:
The RPR port needs to support traffic-redirect to port, link-aggregation and smart-link.