3Com Switch 4200G Configuration Guide

Console Port Login Configuration 13
Figure 4 Set port parameters
Turn on the switch. The user will be prompted to press the Enter key if the switch
successfully completes POST (power-on self test). The prompt (such as <S4200G>)
appears after the user presses the Enter key.
You can then configure the switch or check the information about the switch by
executing commands. You can also acquire help by type the ? character.
Console Port Login
Configuration
Common Configuration Table 12 lists the common configuration of Console port login.
Table 12 Common configuration of Console port login
Configuration Description
Console port
configuration
Baud rate Optional
The default baud rate is 9,600 bps.
Check mode Optional
By default, the check mode of the Console port is set
to “none”, which means no check bit.
Stop bits Optional
The default stop bits of a Console port is 1.
Data bits Optional
The default data bits of a Console port is 8.
AUX user
interface
configuration
Configure the command
level available to the
users logging into the
AUX user interface
Optional
By default, commands of level 3 are available to the
users logging into the AUX user interface.