3Com Switch 4200G Configuration Guide
22 CHAPTER 3: LOGGING IN THROUGH THE CONSOLE PORT
Configure
the Console
port
Set the
baud rate
speed speed-value Optional
The default baud rate of the AUX port
(also the Console port) is 9,600 bps.
Set the
check mode
parity { even | mark |
none | odd | space }
Optional
By default, the check mode of a
Console port is set to none, that is, no
check bit.
Set the stop
bits
stopbits { 1 | 1.5 | 2 } Optional
The default stop bits of a Console port
is 1.
Set the data
bits
databits { 7 | 8} Optional
The default data bits of a Console port
is 8.
Configure the command
level available to users
logging into the user
interface
user privilege level level Optional
By default, commands of level 3 are
available to users logging into the AUX
user interface.
Make terminal services
available to the user
interface
shell Optional
By default, terminal services are
available in all user interfaces.
Set the maximum number
of lines the screen can
contain
screen-length
screen-length
Optional
By default, the screen can contain up to
24 lines.
You can use the screen-length 0
command to disable the function to
display information in pages.
Set history command
buffer size
history-command
max-size value
Optional
The default history command buffer
size is 10. That is, a history command
buffer can store up to 10 commands by
default.
Set the timeout time for
the user interface
idle-timeout minutes [
seconds ]
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no operation is
performed in the user interface within
10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.
Table 18 Console port login configuration with authentication mode being scheme
Operation Command Description