3Com Switch 7750 Configuration Guide Guide

Configuring TP 627
Configuration Procedure
n
Only non-type-A I/O Modules support port-based rate limit.
Configuration Example Set rate limit on GigabitEthernet1/0/1 of the switch
Limit the rate to 10 Mbps.
Configuration procedure:
<SW7750> system-view
[SW7750] interface GigabitEthernet 1/0/1
[SW7750-GigabitEthernet1/0/1] qos
[SW7750-qosb-GigabitEthernet1/0/1] line-rate 10
Configuring TP Refer to “TP” for the introduction to TP.
Configuration
Prerequisites
ACL rules used for traffic identifying are defined. Refer to the ACL module in
the book for defining ACL rules
The limit rate for TP, the actions for the packets within the specified traffic and
the actions for the packets beyond the specified traffic have been specified.
The ports that needs this configuration is specified
Configuration Procedure
of TP
Table 498 Configure rate limit on ports
Operation Command Description
Enter system view system-view -
Enter Ethernet port view
interface interface-type
interface-number
-
Enter QoS view qos -
Configure port-based rate
limit
line-rate [ kbps ] target-rate Required
Display the precedence of the
protocol packet
display protocol-priority
Optional
You can execute the display
command in any view
Table 499 Configure TP
Operation Command Description
Enter system view system-view -
Enter Ethernet port view
interface interface-type
interface-number
-
Enter QoS view qos -
Configure traffic-based TP
traffic-limit { inbound |
outbound } acl-rule [
system-index system-index ]
target-rate
Required
Type-A I/O Modules support
this command.
traffic-limit inbound acl-rule
[ system-index system-index
] [ kbps ] target-rate [ exceed
action ]
Required
Non-type-A I/O Modules
support this command.