3Com Switch 7750 Configuration Guide Guide

Modem Attributes Configuration 71
Configuration Procedure
Configuration Example # Enable Modem call-in and call-out, set the answer mode to auto answer, and set
the timeout time to 45 seconds.
<SW7750> system-view
[SW7750] user-interface aux 0
[SW7750-ui-aux0] modem both
[SW7750-ui-aux0] modem auto-answer
[SW7750-ui-aux0] modem timer answer 45
Operation Command Description
Enter system view system-view -
Enter AUX user interface view user-interface aux 0 -
Enable Modem call-in/call-in
and call-out
modem [ call-in | both ]
Required
Call-in and call-out are
allowed when the command
is executed without any
keyword.
Set the answer mode to auto
answer.
modem auto-answer
Optional
By default, manual answer
mode is adopted.
Configure the carrier
detection timeout time after
off-hook during call-in
connection setup
modem timer answer
seconds
Optional
30 seconds by default.