3Com Switch 7750 Configuration Guide Guide

Displaying the Device Management Configuration 809
Error Packets Monitoring
Configuration Example
Network requirements
Enable error packets monitoring on Ethernet4/0/1 interface and only the
packets that are of runt type are concerned.
Set the interval for detecting error packets to 50 seconds.
Configuration procedure
# Enter system view.
<SW7750> system-view
[SW7750]
# Set the interval for detecting error packets to 50 seconds.
[SW7750] qe monitor errpkt check-time 50
# Enter Ethernet interface view of Ethernet4/0/1.
[SW7750] interface Ethernet 4/0/1
[SW7750-Ethernet4/0/1]
# Specify only detect current interface for error packets of runt type.
[SW7750-Ethernet4/0/1] qe monitor errpkt runt
Displaying the Device
Management
Configuration
After the above configurations, you can execute the display command in any
view to display the operating status of the device management to verify the
configuration effects.
Enable error packets
monitoring
qe monitor errpkt { all |
none | runt }
Required.
If you specify the keyword all
in the command, the switch
detects all error packets on
current interface.
If you specify the keyword
runt, the switch only detects
error packets that are of runt
type on current interface.
If you specify the keyword
none, the switch does not
detect the error packets on
current interface.
Table 627 Configure error packets monitoring
Operation Command Description