3Com Switch 7750 Configuration Guide

Telnet Configuration with Authentication Mode Being Scheme 61
Configuration Example Network requirements
Perform the following configuration for Telnet users logging into VTY 0:
Configure the name of the local user to be “guest”.
Set the authentication password of the local user to 1234567890 (in plain
text).
Set the service type of VTY users to Telnet, and the available command level to
2.
Configure to authenticate users logging into VTY 0 in scheme mode.
Only Telnet protocol is supported in VTY 0.
The screen can contain up to 30 lines.
The history command buffer can store up to 20 commands.
The timeout time of VTY 0 is 6 minutes.
Network diagram
Figure 10 Network diagram for Telnet configuration (with the authentication mode being
scheme)
Configuration procedure
# Enter system view.
<SW7750> system-view
# Create a local user named “guest” and enter local user view.
[SW7750] local-user guest
# Set the authentication password of the local user to 1234567890 (in plain text).
[SW7750-luser-guest] password simple 1234567890
# Set the service type to Telnet, with the available command level being 2.
[SW7750-luser-guest] service-type telnet level 2
# Enter VTY 0 user interface view.
[SW7750] user-interface vty 0
# Configure to authenticate users logging into VTY 0 in the scheme mode.
User PC running Telnet
Ethernet
Ethernet2/0/1