3Com Switch 7750 Configuration Guide
RMON Configuration 749
With the history data management function, you can configure network devices,
such as collecting history data, collecting the data of a specific port periodically
and saving them.
Statistics group
Statistics group contains the statistics of each monitored port on a network device.
An entry in a statistics group is an accumulated value counting from the time
when the statistics group is created.
The statistics include the number of the following items: collisions, packets with
cyclic redundancy check (CRC) errors, undersize (or oversize) packets, broadcast
packets, multicast packets, and received bytes and packets.
With the RMON statistics management function, you can monitor the usage of a
port and make statistics on the errors occurred when the ports are being used.
RMON Configuration
Configuration
Prerequisites
Before performing RMON configuration, make sure the SNMP agents are correctly
configured. For the information about SNMP agent configuration, refer to
“Configuring SNMP Basic Functions” on page 741.
Configuring RMON
Table 599 Configure RMON
Operation Command Description
Enter system view system-view -
Add an event entry rmon event event-entry
[ description string ]{log |
trap trap-community |
log-trap log-trapcommunity |
none } [ owner text ]
Optional
Add an alarm entry rmon alarm entry-number
alarm-variable
sampling-time { delta |
absolute } rising threshold
threshold-value1 event-entry1
falling threshold
threshold-value2 event-entry2
[ owner text ]
Optional
Before adding an alarm entry,
you need to use the rmon
event command to define the
event referenced by the alarm
entry.
Add an extended alarm entry rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-timer { delta |
absolute | changeratio }
rising_threshold
threshold-value1 event-entry1
falling_threshold
threshold-value2 event-entry2
ent
rytype { forever | cycle
cycle-period } [ owner text ]
Optional
Before adding an extended
alarm entry, you need to use
the rmon event command to
define the event referenced
by the extended alarm entry.
Enter Ethernet port view interface interface-type
interface-number
-
Add a history entry rmon history entry-number
buckets number interval
sampling-interval [ owner
text ]
Optional