3Com Switch 7750 Configuration Guide
798 CHAPTER 73: BIMS CONFIGURATION
6 The device verifies the device software obtained from the BIMS center and
updates it to the local. Then the device sends an acknowledgement to the BIMS
center.
7 Upon receipt of the acknowledgement, the BIMS center logs the event and sends
back a response.
BIMS Device
Configuration Tasks
BIMS is a convenient management tool. It provides an intelligent function for
upgrading the configuration file and applications. BIMS device configuration
involves the following two parts:
■ Basic configuration. For details, see “Basic Configuration of BIMS Device” on
page 798.
■ Configuration of BIMS access mode. For details, see “Configuring BIMS Access
Mode” on page 799.
c
CAUTION:
■ When you use the BIMS device to upgrade the host software and configuration
file, the name of the file downloaded and saved to the local device is the same
as that on the BIMS device.
■ If the device experiences power failure during the upgrade of host software or
configuration file, it is possible that old host software or configuration file is
deleted and the new file is not saved yet. In this case, the upgrade will fail, the
configuration on the device will be lost, and eventually the BIMS cannot
manage the device.
Basic Configuration of
BIMS Device
c
CAUTION: The same port number must be configured on the BIMS device and on
the BIMS center.
Table 632 BIMS device basic configuration
Operation Command Description
Enter system view system-view -
Enable BIMS on the
device
bims enable Required
By default, BIMS is disabled on the
device.
Configure the unique
identifier of the device
bims device-id string Required
By default, no unique identifier of
the device is configured.
Configure the IP
address and port
number of the BIMS
center
bims ip address ip-address
[ port portnumber ]
Required
By default, no IP address and port
number of the BIMS center are
configured.
Configure the shared
key between the BIMS
device and BIMS center
bims sharekey { simple |
cipher } sharekey
Required
By default, no shared key is
configured.
Configure the source IP
address in the packet
sent by the BIMS device
bims source ip-address
ip-address
Optional
By default, no source IP address in
the packet sent by the BIMS device is
configured.