3Com Switch 8800 Family Command Reference Guide

Basic System Configuration and Management Commands 1027
View
User view
Parameter
zone-name: Name of the time zone, which is a character with the length ranging
from 1 to 32.
add: Tme is adding compared with the UTC.
minus: Time is minus compared with the UTC.
HH:MM:SS: Time (hour/minute/second).
Description
Use the clock timezone command to set the information of the local time zone.
Use the undo clock timezone command to restore to the default Universal Time
Coordinated (UTC) time zone.
After the configuration takes effect, the display clock command can be used to
check it. Besides, the time of the log or debug information uses the local time
after the adjustment of the time zone and summer time.
Related command: clock summer-time.
Example
# Set the name of the local time zone to Z5 with five hours adhead compared with
the UTC time.
<SW8800> clock timezone z5 add 05:00:00
quick-ping enable Syntax
quick-ping enable
undo quick-ping enable
View
System view
Parameter
None
Description
Use the quick-ping enable command to enable the PING distribution function.
Use the undo quick-ping enable command to disable the PING distribution
function.
By default, the PING distribution function is enabled.
Example
# Enable the ping distribution function.