3Com Switch 8800 Family Command Reference Guide
54
RMON CONFIGURATION COMMANDS
RMON Configuration
Commands
display rmon alarm Syntax
display rmon alarm [ alarm-table-entry ]
View
Any view
Parameter
alarm-table-entry: Alarm table entry index.
Description
Use the display rmon alarm command to view RMON alarm information.
Related command: rmon alarm.
Example
# Display the RMON alarm information.
<SW8800> display rmon alarm
Alarm table 1 owned by monitor is VALID.
Samples type : delta
Variable formula : 1.3.6.1.2.1.16.1.1.1.3.1<etherStatsDropEvents.1>
Description : Ethernet5/1/1
Sampling interval : 10(sec)
Rising threshold : 10(linked with event 1)
Falling threshold : 2(linked with event 1)
When startup enables : risingOrFallingAlarm
Latest value : 0
Tab le 129 Description on the fields of the display rmon alarm command
Field Description
Alarm table 1 Index 1 in alarm table
monitor Owner
VALID The alarm entry corresponding to this index is valid.
Samples type Type of sampling
Variable formula Variable parameters
Description Description information
Sampling interval Time interval for sampling
Rising threshold is 1000 The rising threshold is 1000.
Falling threshold is 100 The falling threshold is 100.