3Com Switch 8800 Family IPsec Module Configuration and Command reference Guide
322 CHAPTER 18: ACCESS CONTROL LIST CONFIGURATION COMMANDS
[SecBlade_FW-acl-adv-3001] rule 7 comment Allow FTP from any source
to host 172.16.0.1
Time-range
Configuration
Commands
display time-range Syntax
display time-range { all | time-name }
View
Any view
Parameter
time-name: Name of the time range.
all: Displays all the configured time ranges.
Description
Use the display time-range command to view the configuration and the status
of time range. For the active time range at present, it displays "active" and for the
inactive time range, it displays "inactive".
Since there is a time deviation when the system updates acl status, which is about
1 minute, but display time-range will display the information of time range at
the current time exactly. Thus, the following case may happen: use the command
display time-range to find that a time range is activated but the acl that should
be active in the time range is inactive. This case is normal.
Example
# Display all time ranges.
[SecBlade_FW] display time-range all
# Display the time range named trname.
[SecBlade_FW] display time-range trname
Current time is 02:49:36 2/15/2003 Saturday
Time-range : trname ( Inactive )
14:00 to 16:00 off-day from 00:00 12/1/2002 to 00:00 12/1/2003
time-range Syntax
time-range time-name [ start-time to end-time ] [ days ] [ from time1 date1 ] [ to
time2 date2 ]
undo time-range time-name [ start-time to end-time ] [ days ] [ from time1
date1 ] [ to time2 date2 ]
View
System view