H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – Infomation Center
H3C S7500 Series Ethernet Switches Chapter 1
Information Center Commands
1-3
Field Description
Console:
Information about the console port, including name and
number of its information channel
Monitor:
Information about the monitor port, including name and
number of its information channel
SNMP Agent:
Information about SNMP Agent, including name and number
of its information channel
Log buffer:
Information about the log buffer, including its state
(enabled/disabled), maximum size, current size, number of
current messages, information channel name and number,
number of dropped messages, and number of overwritten
messages
Trap buffer:
Information about the trap buffer, including its state
(enabled/disabled), maximum size, current size, number of
current messages, channel number and name, number of
dropped messages, and number of overwritten messages
Information
timestamp setting
Information about time stamp, describing the time stamp
formats of log information, trap information, and debugging
information
1.1.3 display logbuffer
Syntax
display logbuffer [ level severity | size buffersize ]* [ | { begin | exclude | include }
regular-expression ]
View
Any view
Parameters
level severity: Specifies an information severity level. The severity argument ranges
from 1 to 8.
Table 1-2 Severity definitions made on the information center
Severity Value Description
emergencies 1 Emergent errors
alerts 2 Errors that need to be corrected immediately
critical 3 Critical errors
errors 4
Errors that need to be considered but are not
critical
warnings 5 Warnings that prompt possible errors