H3C S7500 Series Ethernet Switches
Chapter 1 Basic System Configuration
and Debugging Commands
1-7
1.2 System Status/Information Display Commands
1.2.1 display clock
Syntax
display clock
View
Any view
Parameters
None
Description
Use the display clock command to display the current date and time of the system, so
that you can adjust them if they are wrong.
The maximum date and time that can be displayed by this command is 23:59:59
9999/12/31.
Related commands: clock datetime.
Examples
# Display the current date and time of the system.
<H3C> display clock
18:36:31 beijing Sat 2002/02/02
Time Zone : beijing add 01:00:00
Summer-Time : bj one-off 01:00:00 2003/01/01 01:00:00 2003/08/08 01:00:00
Table 1-1 Description on the fields of the display clock command
Field Description
18:36:31 beijing Sat 2002/02/02 Current date and time of the system
Time Zone Configured time zone information
Summer-Time Configured daylight saving time information
1.2.2 display debugging
Syntax
display debugging [ interface interface-type interface-number ] [ module-name ]