H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – RRPP
H3C S7500 Series Ethernet Switches Chapter 1
RRPP Configuration Commands
1-12
Parameters
hello-value: Time interval, at which the primary port of the master node sends the
health detection packet, in the range of 1 to 10, in seconds. The default value is 1
second.
fail-value: Timeout time, at which the secondary port of the master node receives the
health detection packet, in the range of 3 to 30, in seconds. The default value is 3
seconds.
Description
Use the timer command to configure the time values of the Hello timer and Fail timer in
the RRPP domain.
Use the undo timer command to restore the default time values.
The Fail timer value cannot be less than three times the Hello timer value.
Examples
# Set the time interval at which the primary port of the master node in RRPP domain 1
sends the health detection packet to 2 seconds, and set the timeout time for the
secondary port of the master node in the RRPP domain 1 to receive health detection
packets to 7 seconds.
<H3C> system-view
[H3C] rrpp domain 1
[H3C-rrpp-domain1] timer hello-timer 2 fail-timer 7
# Restore the default timer values for RRPP domain 1.
<H3C> system-view
[H3C] rrpp domain 1
[H3C-rrpp-domain1] undo timer