H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – AAA & RADIUS & HWTACACS & EAD
H3C S7500 Series Ethernet Switches
Chapter 1 AAA & RADIUS & HWTACACS
Configuration Commands
1-49
Use the undo timer command to restore the default response timeout time of RADIUS
server.
Note that:
z If the switch gets no response from the RADIUS server after sending out a
RADIUS request (authentication/authorization request or accounting request) and
waiting for a time, it should retransmit the packet to ensure that the user can obtain
the RADIUS service. This wait time is called response timeout time of RADIUS
server; and the timer in the switch system that is used to control this time is called
the response timeout timer of RADIUS server. You can use the timer command to
set the timeout time of this timer.
z Appropriately setting the timeout time of this timer according to the network
situation can improve the performance of the system.
z The timer command achieves the same result as the timer response-timeout
command does.
Related commands: radius scheme, retry.
Examples
# Set the timeout time of the response timeout timer for the RADIUS scheme radius1 to
5 seconds.
<H3C>system-view
System View: return to User View with Ctrl+Z.
[H3C] radius scheme radius1
[H3C-radius-radius1] timer 5
1.2.26 timer quiet
Syntax
timer quiet minutes
undo timer quiet
View
RADIUS scheme view
Parameters
minutes: Wait time, ranging from 1 minute to 255 minutes. By default, it is 5 minutes.
Description
Use the timer quiet command to set the wait time for the primary server to restore the
active state.
Use the undo timer quiet command to restore the default wait time.
Wait time works as follows: