H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – SNMP and RMON
H3C S7500 Series Ethernet Switches Chapter 1
SNMP Configuration Commands
1-6
0 Messages which represented an illegal operation for the community supplied
0 ASN.1 or BER errors in the process of decoding
9266 Messages passed from the SNMP entity
0 SNMP PDUs which had badValue error-status
0 SNMP PDUs which had genErr error-status
11 SNMP PDUs which had noSuchName error-status
0 SNMP PDUs which had tooBig error-status (Maximum packet size 2000)
33029 MIB objects retrieved successfully
26 MIB objects altered successfully
714 GetRequest-PDU accepted and processed
8514 GetNextRequest-PDU accepted and processed
10 GetBulkRequest-PDU accepted and processed
9230 GetResponse-PDU accepted and processed
1 SetRequest-PDU accepted and processed
34 Trap PDUs accepted and processed
1.1.6 display snmp-agent sys-info
Syntax
display snmp-agent sys-info [ contact | location | version ]*
View
Any view
Parameters
contact: Displays the contact information of the current device.
location: Displays the physical location of the current device.
version: Displays the version information of the SNMP running in the system.
Description
Use the display snmp-agent sys-info command to view the system contact
(sysContact) string, physical location string, and the current SNMP version.
This command displays all information if you choose no parameter.
Examples
# Display the sysContact string.
<H3C> display snmp-agent sys-info contact
The contact person for this managed node:
Hangzhou H3C Technologies Co., Ltd.
The above information indicates that the contact of this device is Hangzhou H3C
Technologies Co., Ltd.