H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – SSH Terminal Service
H3C S7500 Series Ethernet Switches
Chapter 1 SSH Terminal Service
Configuration Commands
1-4
Description
Use the display ssh server command to display the status or session information
about the SSH server.
Related commands: ssh server authentication-retries, ssh server timeout.
Examples
# Display the status information about the SSH server.
<H3C> display ssh server status
SSH version : 1.99
SSH connection timeout : 60 seconds
SSH server key generating interval : 0 hours
SSH Authentication retries : 3 times
SFTP Server: Enable
Caution:
z If you use the ssh server compatible-ssh1x enable command to configure the
server to be compatible with the client of SSH1.x version, the SSH version will be
displayed as 1.99.
z If you use the undo ssh server compatible-ssh1x enable command to configure
the server to be not compatible with the client of SSH1.x version, the SSH version
will be displayed as 2.0.
# Display the session information about the SSH server.
<H3C> display ssh server session
Conn Ver Encry State Retry SerType Username
VTY 0 2.0 AES started 0 stelnet kk
VTY 1 2.0 AES started 0 sFTP abc
Table 1-1 Description on the fields of the display ssh server session command
Field Description
Conn Number of VTY interface used for user login
Ver SSH version
Encry
Encryption algorithm used by SSH. Encry is short for
encryption. The encryption algorithms in common use are
advanced encryption standard (AES), data encryption
standard (DES), and triple DES (3DES).
State Current state