H3C S7500 Series Ethernet Switches Installation Manual
Installation Manual
H3C S7500 Series Ethernet Switches Chapter 2 Line Processing Units
2-35
Note:
When using the LS81T32P as an LPU of the S7503/S7506/S7506R switch, you can
only use it together with a Salience III or Salience III Plus SRPU.
z If you use the LS81T32P together with a Salience III Plus SRPU, you can insert it
into any LPU slot on the S7503/S7506/S7506R.
z If you use the LS81T32P together with a Salience III SRPU, you can only insert it
into one of the last two LPU slots on the S7503/S7506/S7506R (slot 2 or 3 for the
S7503, slot 5 or 6 for the S7506, and slot 6 or 7 for the S7506R).
2.16.2 Panel and LEDs
Figure 2-44 LS81T32P panel
(1) Silkscreen of the LPU name (2) Captive screw
(3) LPU edge (green) (4) Ejector lever
(5) 1000Base-X-SFP port status LED (6) 1000Base-X-SPF port
(7) 10/100/1000Base-T Ethernet port
Figure 2-45 Partially amplified view of the LS81T32P panel
The following table describes the LED of the LS81T32P: