H3C S7500 Series Ethernet Switches Operation Manual
Operation Manual – GVRP
H3C S7500 Series Ethernet Switches Chapter 1
GVRP Configuration
1-6
Table 1-2 Relations between the timers
Timer Lower threshold Upper threshold
Hold 10 centiseconds
This upper threshold is less than
or equal to one-half of the timeout
time of the Join timer. You can
change the threshold by changing
the timeout time of the Join timer.
Join
This lower threshold is greater
than or equal to twice the timeout
time of the Hold timer. You can
change the threshold by changing
the timeout time of the Hold timer.
This upper threshold is less than
one-half of the timeout time of the
Leave timer. You can change the
threshold by changing the timeout
time of the Leave timer.
Leave
This lower threshold is greater
than twice the timeout time of the
Join timer. You can change the
threshold by changing the timeout
time of the Join timer.
This upper threshold is less than
the timeout time of the LeaveAll
timer. You can change the
threshold by changing the timeout
time of the LeaveAll timer.
LeaveAll
This lower threshold is greater
than the timeout time of the Leave
timer. You can change threshold
by changing the timeout time of
the Leave timer.
32,765 centiseconds
Note:
The recommended settings of GARP timers:
z GARP Hold timer: 100 centiseconds (1 second).
z GARP Join timer: 600 centiseconds (6 seconds).
z GARP Leave timer: 3000 centiseconds (30 seconds).
z GARP LeaveAll timer: 12000 centiseconds (2 minutes).
1.3 Displaying and Maintaining GVRP
To do… Use the command… Remarks
Display GARP statistics
display garp statistics [ interface
interface-list ]
Display the settings of the
GARP timers
display garp timer [ interface
interface-list ]
Display GVRP statistics
display gvrp statistics [ interface
interface-list ]
Display the global GVRP
status
display gvrp status
Available in
any view.