H3C S7500 Series Ethernet Switches Operation Manual

Operation Manual – Login
H3C S7500 Series Ethernet Switches Chapter 2
Logging in through the Console Port
2-16
z Set the service type of the local user to Terminal.
z Configure to authenticate users logging in through the console port in the scheme
mode.
z The commands of level 2 are available to users logging into the AUX user
interface.
z The baud rate of the console port is 19,200 bps.
z The screen can contain up to 30 lines.
z The history command buffer can store up to 20 commands.
z The timeout time of the AUX user interface is 6 minutes.
II. Network diagram
User PC running Telnet
Ethernet
Ethernet1/0/1
eing scheme)
Figure 2-7 Network diagram for AUX user interface configuration (with the
authentication mode b
III. Configuration procedure
# Enter system view.
<H3C> system-view
# Create a local user named guest and enter local user view.
[H3C] local-user guest
# Set the authentication password to 123456 (in plain text).
[H3C-luser-guest] password simple 123456
# Set the service type to Terminal, with the user level being 2.
[H3C-luser-guest] service-type terminal level 2
[H3C-luser-guest] quit
# Enter AUX user interface view.
[H3C] user-interface aux 0
# Configure to authenticate users logging in through the console port in the scheme
mode.
[H3C-ui-aux0] authentication-mode scheme