H3C S7500 Series Ethernet Switches Operation Manual

Operation Manual – Login
H3C S7500 Series Ethernet Switches Chapter 4
Logging in Using Modem
4-6
To do… Use the command… Remarks
Enter system view
system-view
Enter AUX user interface
view
user-interface aux 0 —
Enable Modem
call-in/call-in and call-out
modem [ call-in | both ]
Required
Call-in and call-out are
allowed when the
command is executed
without any keyword.
Set the answer mode to
auto answer.
modem auto-answer
Optional
By default, manual
answer mode is adopted.
Configure the carrier
detection timeout time
after off-hook during
call-in connection setup
modem timer answer
seconds
Optional
30 seconds by default.
4.5.3 Configuration Example
z Enable Modem call-in and call-out, set the answer mode to auto answer, and set
the timeout time to 45 seconds.
Configuration procedure:
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] user-interface aux 0
[H3C-ui-aux0] modem both
[H3C-ui-aux0] modem auto-answer
[H3C-ui-aux0] modem timer answer 45