H3C S7500 Series Ethernet Switches Operation Manual

Operation Manual – System Maintenance and Debugging
H3C S7500 Series Ethernet Switches Chapter 4
Device Management
4-11
4.7 Displaying the Device Management Configuration
After the above configurations, you can execute the display command in any view to
display the operating status of the device management to verify the configuration
effects.
Follow these steps to display the operating status of the device management:
To do… Use the command… Remarks
Display the APP to be adopted
at reboot
display boot-loader
Display the module type and
operating status of each board
display device [ detail | [ shelf
shelf-no ] [ frame frame-no ] [ slot
slot-number ] ]
Display information about
environment used by a switch
display environment
Display the operating status of
the built-in fan
display fan [ fan-id ]
Display the usage of s switch display cpu [ slot slot-number ]
Display memory usage of a
switch
display memory [ slot slot-number
| limit ]
Display the operating status of
the power supply
display power [ power-id ]
Available in
any view.
4.8 Remote Switch Update Configuration Example
I. Network requirements
Telnet to the switch from a PC remotely and download applications from the FTP server
to the Flash memory of the switch to remotely update the switch software by using the
device management commands through CLI.
The switch acts as the FTP client, and the remote PC serves as both the configuration
PC and the FTP server.
Perform the following configuration on the FTP server.
z Configure an FTP user, whose name and password are switch and hello
respectively. Authorize the user with the read-write right of the Switch directory on
the PC.
z Make appropriate configuration so that the IP address of a VLAN interface on the
switch is 1.1.1.1, the IP address of the PC is 2.2.2.2, and the switch and the PC is
reachable to each other.