H3C S7500E Series Ethernet Switches Operation Manual
Operation Manual – QinQ-BPDU Tunneling
H3C S7500E Series Ethernet Switches Chapter 1 QinQ Configuration
1-7
z Third-party devices are deployed between Provider A and Provider B, with a TPID
value of 0x8200.
The expected result of the configuration is as follows:
z VLAN 10 of Customer A and Customer B can intercommunicate across VLAN
1000 on the public network.
z VLAN 20 of Customer A and Customer C can intercommunicate across VLAN
2000 on the public network.
z Frames of the VLANs other than VLAN 20 of Customer A can be forwarded to
Customer D across VLAN 3000 on the public network.
II. Network diagram
Eth2/0/1
Eth2/0/2
Eth2/0/3
Eth2/0/1
Eth2/0/2
VLAN 10, VLAN 20
VLAN 10 VLAN 20
Customer B
Customer A
Customer C
Provider BProvider A
Public network
VLAN 1000/2000/3000
TPID=0x8200
Customer D
Eth2/0/3
Figure 1-3 Network diagram for QinQ configuration
III. Configuration procedure
Note:
With this configuration, the user must allow the QinQ packets to pass between the
devices of the service providers.
1) Configuration on Provider A
# Enter system view.
<ProviderA> system-view
z Configuration on Ethernet 2/0/1