H3C S7500E Series Ethernet Switches Operation Manual

Operation Manual – Login
H3C S7500E Series Ethernet Switches Chapter 2 Logging in Through the Console Port
2-9
2.4.2 Configuration Example
I. Network requirements
Assume the switch is configured to allow you to login through Telnet, and your user
level is set to the administrator level (level 3). After you telnet to the switch, you need to
limit the console user at the following aspects.
z The user is not authenticated when logging in through the Console port.
z Commands of level 2 are available to user logging into the AUX user interface.
z The baud rate of the Console port is 19200 bps.
z The screen can contain up to 30 lines.
z The history command buffer can contain up to 20 commands.
z The timeout time of the AUX user interface is 6 minutes.
II. Network diagram
User PC running Telnet
Ethernet
Ethernet2/0/1
Figure 2-5 Network diagram for AUX user interface configuration (with the
authentication mode being none)
III. Configuration procedure
# Enter system view.
<H3C> system-view
# Enter AUX user interface view.
[H3C] user-interface aux 0
# Specify not to authenticate the user logging in through the Console port.
[H3C-ui-aux0] authentication-mode none
# Specify commands of level 2 are available to the user logging into the AUX user
interface.
[H3C-ui-aux0] user privilege level 2
# Set the baud rate of the Console port to 19200 bps.
[H3C-ui-aux0] speed 19200