H3C S7500E Series Ethernet Switches Operation Manual

Operation Manual – Login
H3C S7500E Series Ethernet Switches Chapter 2 Logging in Through the Console Port
2-16
To do… Use the command… Remarks
Set history
command buffer size
history-command
max-size value
Optional
The default history command
buffer size is 10. That is, a history
command buffer can store up to 10
commands by default.
Set the timeout time
for the user interface
idle-timeout minutes
[ seconds ]
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no
operation is performed in the user
interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.
Note that the level the commands of which are available to users logging into a switch
depends on the authentication-mode scheme [ command-authorization ] command,
the user privilege level level command, and the service-type terminal [ level level ]
command, as listed in
Table 2-6.