H3C S7500E Series Ethernet Switches Operation Manual
Operation Manual – Multicast
H3C S7500E Series Ethernet Switches Chapter 5 PIM Configuration
5-27
device, the device can receive these two types of messages and record the RP
information carried in such messages.
Follow these steps to enable auto-RP:
To do... Use the command... Remarks
Enter system view
system-view
—
Enter PIM view
pim
—
Enable auto-RP
auto-rp enable
Optional
Disabled by default
IV. Configuring C-RP timers
To enable the BSR to distribute the RP-set information within the PIM-SM domain,
C-RPs must periodically send C-RP-Adv messages to the BSR. The BSR learns the
RP-set information from the received messages, and encapsulates its own IP address
together with the RP-set information in its bootstrap messages. The BSR then floods
the bootstrap messages to all PIM routers (224.0.0.13) in the network.
Each C-RP encapsulates a timeout value in its C-RP-Adv message. Upon receiving
this message, the BSR obtains this timeout value and starts a C-RP timeout timer. If the
BSR fails to hear a subsequent C-RP-Adv message from the C-RP when the timer
times out, the BSR assumes the C-RP to have expired or become unreachable.
Follow these steps to configure C-RP timers:
To do... Use the command... Remarks
Enter system view
system-view
—
Enter PIM view
pim
—
Configure the C-RP-Adv
interval
c-rp
advertisement-interval
interval
Optional
60 seconds by default
Configure C-RP timeout
time
c-rp holdtime interval
Optional
150 seconds by default