H3C S7500E Series Ethernet Switches Operation Manual
Operation Manual – Multicast
H3C S7500E Series Ethernet Switches Chapter 5 PIM Configuration
5-51
toward the multicast source. Switches on the SPT path (Switch A and Switch D) have
generated an (S, G) entry, while Switch E, which is not on the SPT path, does not have
multicast routing entries. You can use the display pim routing-table command to view
the PIM routing table information on each switch. For example:
# View the PIM routing table information on Switch A.
[SwitchA] display pim routing-table
Total 0 (*, G) entry; 1 (S, G) entry
(10.110.5.100, 232.1.1.1)
Protocol: pim-ssm, Flag:
UpTime: 00:13:25
Upstream interface: Vlan-interface101
Upstream neighbor: 192.168.1.2
RPF prime neighbor: 192.168.1.2
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface100
Protocol: igmp, UpTime: 00:13:25, Expires: -
The information on Switch B and Switch C is similar to that on Switch A.
# View the PIM routing table information on Switch D.
[SwitchD] display pim routing-table
Total 0 (*, G) entry; 1 (S, G) entry
(10.110.5.100, 232.1.1.1)
Protocol: pim-ssm, Flag: LOC
UpTime: 00:12:05
Upstream interface: Vlan-interface300
Upstream neighbor: NULL
RPF prime neighbor: NULL
Downstream interface(s) information:
Total number of downstreams: 1
1:: Vlan-interface105
Protocol: pim-ssm, UpTime: 00:12:05, Expires: 00:03:25