HP 10500 Switch Series - HP 10500-CMW710-R2105P05 Release Notes
9
Upgrading an IRF fabric
Preparing for the upgrade
1. Telnet to the switch or log in through the console port. (Details not shown.)
2. Display device information.
<Sysname>display device
Chassis Slot Type State Subslot Soft Ver Patch Ver
1 0 LSU1SUPB0 Master 0 10500-2102 None
1 1 LSU1SUPB0 Standby 0 10500-2102 None
1 2 LSU1GP24TXSE0 Normal 0 10500 -2102 None
1 3 LSU1TGX4SE0 Normal 0 10500 -2102 None
1 4 NONE Absent 0 NONE None
1 5 NONE Absent 0 NONE None
1 6 LSU1FAB04A0 Normal 0 10500 -2102 None
1 7 NONE Absent 0 NONE None
1 8 NONE Absent 0 NONE None
1 9 NONE Absent 0 NONE None
2 0 LSU1SUPB0 Standby 0 10500-2102 None
2 1 LSU1SUPB0 Standby 0 10500-2102 None
2 2 LSU1GP24TXSE0 Normal 0 10500 -2102 None
2 3 LSU1TGX4SE0 Normal 0 10500 -2102 None
2 4 NONE Absent 0 NONE None
2 5 NONE Absent 0 NONE None
2 6 LSU1FAB04A0 Normal 0 10500 -2102 None
2 7 NONE Absent 0 NONE None
2 8 NONE Absent 0 NONE None
2 9 NONE Absent 0 NONE None
The output shows that two switches form an IRF fabric. The following table shows MPU information.
Table 8 MPU information of the IRF fabric
MPU role
Member ID
Slot number
Master MPU (also called the "global active MPU")
1
0
Standby MPU
1
1
Standby MPU
2
0
Standby MPU
2
1
3. Verify that all the MPUs have enough free storage space for the upgrade files:
# On the global active MPU:
<Sysname> dir
Directory of flash:
0 -rw- 74948608 Nov 21 2012 09:35:45 10500.ipe
1 -rw- 2236 Jan 08 2013 09:07:45 210231A1Y30000000006201301071608474
6260.ak
2 -rw- 2235 Jan 08 2013 09:37:45 210231A1Y300000000062013010 80958534
8219.ak