HP 11900 Switch Series - HP 11900-CMW710-R2105 Release Notes
5
Workaround: Make sure the switches have similar card configurations, can back up each other,
and are rebooted at the same time. If the IRF fabric splits, reboot the smallest IRF system so the
switches can join the system to re-form a 4-chassis fabric.
LSV7D001930
Symptom: After an incompatible ISSU on an IRF fabric that is the root of the TRILL multicast
distribution tree, the TRILL nickname (bridge MAC address) of the IRF fabric is changed but the root
name is not changed to the new name, resulting in a 20 -minute interruption of multicast traffic.
Condition: This symptom occurs after an incompatible ISSU on an IRF fabric that is the root of the
TRILL multicast distribution tree. After the ISSU, the TRILL nickname (bridge MAC address) of the IRF
fabric is changed, but the root name of the TRILL multicast distribution tree is not changed to the new
name.
Workaround: Before you perform the incompatible ISSU, reduce the root priority for the IRF fabric
to let it become a non-root RB. After the ISSU, increase the root priority for the IRF fabric to become
the root.
LSV7D000346
Symptom: If PFC is enabled on an IRF port, the IRF fabric might split.
Condition: This symptom might occur if PFC is enabled on an IRF port.
Workaround: Do not enable PFC on an IRF port.
List of resolved problems
Resolved problems in R2105
None
Related documentation
Documentation set
HP FlexFabric 11908-V Switch Installation Guide
HP FlexFabric 11900 Switch Series Configuration Guides (R2100 series)
HP FlexFabric 11900 Switch Series Command References (R2100 series)
Obtaining documentation
To find related documents, browse to the Manuals page of the HP Business Support Center website:
http://www.hp.com/support/manuals