HP 12500 Switch Series - 12500-CMW710-R7129 Release Notes
8
Open problems and workarounds
None.
List of resolved problems
Resolved problems in 12500-CMW710-R7129
TCD003126
Symptom: On an IRF fabric that acts as an ED device in an EVI network, if an EVI link goes
down and then recovers because of IGP flapping when a master/subordinate switchover
occurs, the ED device might not send its MAC address to the peer device within three minutes.
As a result, the peer device cannot learn the MAC address and fails to communicate with the
ED device.
Condition: This symptom might occur when the following conditions exist:
The IRF fabric comprises 12500 switches and acts as an ED device in an EVI network.
A master/subordinate switchover occurs on the IRF fabric.
An EVI link goes down and then recovers because of IGP flapping.
Resolved problems in 12500-CMW710-R7128
LPD044981
Symptom: On an EVI edge device, half of ports on a card in a non-Admin MDC fail to forward
site-to-site unicast traffic.
Condition:
The switch is an EVI edge device.
The allocate interface command is executed twice to assign ports on a card to a
non-Admin MDC. The first time it is executed ports in the first half of the port range are
assigned. The second time it is executed ports in the second half of the port range are
assigned.
LPD046752
Symptom: If too many static routes in different VPNs use the same outgoing interface, routing
table entry insufficiency might occur.
Condition: Static routes in different VPNs use the same outgoing interface.
LPD049405
Symptom: Device login password can be obtained by accessing the hh3cUserPassword node
of hh3cUserInfoTable with SNMP.
Condition: The hh3cUserPassword node of hh3cUserInfoTable is accessed with SNMP.