HP 7500-CMW520-R6701 Release Notes
HP 7500-CMW520-R6701 Release Notes HP 7500-CMW520-R6701 Release Notes Keywords: 7500 Abstract: This release notes describes the 7500-CMW520-R6701 release with respect to hardware and software compatibility, released features and functions, software upgrading, and documentation. Acronyms: Acronym Full spelling CMW Comware MIB Management Information Base PoE Power over Ethernet IRF Intelligent Resilient Framework Hewlett-Packard Development Company, L.P.
HP 7500-CMW520-R6701 Release Notes Contents Important information··················································································································································· 4 Version information······················································································································································ 4 Version number ············································································································
HP 7500-CMW520-R6701 Release Notes List of Tables Table 1 Version history ................................................................................................................... 4 Table 2 HP 7500 product family matrix ............................................................................................ 4 Table 3 Hardware and software compatibility matrix.......................................................................... 5 Table 4 7500 series hardware features......................
HP 7500-CMW520-R6701 Release Notes Important information In this software the format of the configuration files has been changed. To avoid any problems downgrading software, please backup the configuration file before upgrading. More details may be found in the Open problems and workarounds section below. Version information Version number Comware software, Version 5.20.105, Release 6701 Note: You can view the version numbers with the command display version in any view. See Note ①.
HP 7500-CMW520-R6701 Release Notes HP 7500 3Com 7900E H3C S7500E HP 7502 3Com S7902E H3C S7502E HP 7503-S None H3C S7503E-S HP 7503 3Com S7903E H3C S7503E HP 7506 3Com S7906E H3C S7506E HP 7506-V 3Com S7906E-V H3C S7506E-V HP 7510 3Com S7910E H3C S7520E Table 3 Hardware and software compatibility matrix Item Specifications Product family HP 7500 series, 3Com S7900E series and H3C S7500E series HP 7502/7503-S/7503/7506/7506-V/7510 Hardware platform 3Com S7902E/S7903E/S7906E/S7906E-
HP 7500-CMW520-R6701 Release Notes Display the system software and Boot ROM versions: [HP] display version HP Comware Platform Software Comware Software, Version 5.20.105, Release 6701 ------Note① Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P.
HP 7500-CMW520-R6701 Release Notes 2. It takes more than half an hour to collect diagnostic information when the IRF has many configuration parameters. 3. The hp 7500 product family supports four IRF members in R6635. There are several setup and configuration limitation, please check the Command Line Manual and Operation Manual of R6635 for detail. Feature list Hardware features Table 4 7500 series hardware features Item Specification HP 7502: 175 x 436 x 420 mm (6.89 x 17.17 x 16.54 in.
HP 7500-CMW520-R6701 Release Notes Item Specification 423.52W (HP 7503) 707.2W (HP 7506) 710.
HP 7500-CMW520-R6701 Release Notes Item Transceiver modules and cables Specification JC669A HP 7500 20-port Gig-T / 4-port GbE Combo PoE-upgradable SC Module JD191A HP 7500 8-port 10-GbE XFP SD Module JC713A HP 7500 8-port 10-GbE XFP SD TAA-compliant Module JD229B HP 7500 48-port Gig-T PoE+ SD Module JC712A HP 7500 48-port Gig-T PoE+ SD TAA-compliant Module JD230A HP 7500 24-port GbE SFP / 2-port 10-GbE XFP SD Module JC714A HP 7500 24-port GbE SFP / 2-port 10-GbE XFP SD TAA-compliant Module
HP 7500-CMW520-R6701 Release Notes Item Specification JD096B HP X240 10G SFP+ SFP+ 1.
HP 7500-CMW520-R6701 Release Notes Category Features VLAN) IEEE 802.1Q IEEE802.1p RSTP(802.1w) MSTP(802.1s) LACP(802.
HP 7500-CMW520-R6701 Release Notes Category Features IS-ISv6 IGMP Snooping IGMP MLD Snooping MLD Multicast PIM-DM PIM-SM PIM-SSM BIDIR-PIM MSDP Remark 802.1p, DSCP, IP precedence, or local precedence by ACL rule Map to output queue by 802.
HP 7500-CMW520-R6701 Release Notes Category Features Console login AUX login User access control Telnet (VTY) login SSH login FTP login XMODEM Ping DNS client DHCP server DHCP client DHCP relay agent Application protocols DHCP snooping Telnet FTP client FTP server TFTP client NTP client/server VRRP Availability Dual fabric IRF ISSU RADIUS TACACS+ Security EAD Portal 802.1X Port Security MPLS MPLS LDP MPLS L3VPN MPLS L2VPN Hewlett-Packard Development Company, L.P.
HP 7500-CMW520-R6701 Release Notes Version updates Feature updates Table 6 Feature updates Item Description 7500-CMW520-R6701 Hardware feature updates None New features: Advertisement via LLDP of dynamically assigned VLAN No cached Username / password loop, IP phone never prompts user for credentials LLDP not recognized by A-series switches RADIUS attribute 27 & 29 required in ‘display’ command Mac-authentication delay timer (mac-authentication should only trigger once it expires) Software feature upda
HP 7500-CMW520-R6701 Release Notes Item Description 7500-CMW520-F6630 Hardware feature updates None New features: Radius Fail Vlan Software feature updates Radius Call Check Parameter Reinitialization of 802.
HP 7500-CMW520-R6701 Release Notes Command line updates Table 7 Command line updates Item Description 7500-CMW520-R6701 New commands Reference to HP 7500 Switch Series Command References (R6700 series)-6W101 Removed commands None Modified commands None 7500-CMW520-R6635 New commands None Removed commands None Modified commands None 7500-CMW520-F6632 New commands None Removed commands None Modified commands display connection ucib index: add ‘Session Timeout’ and ’Termination Action’ 750
HP 7500-CMW520-R6701 Release Notes Item Description VLAN parameters added for some spanning tree configuration commands MIB updates Table 8 MIB updates Item MIB file Module Description 7500-CMW520-R6701 sysDescr rfc1213.mib RFC1213-MIB Removing "A" from 7500 sysObjectID rfc1213.mib RFC1213-MIB Removing "A" from 7500 entPhysicalSoftwa reRev hh3c-entity-vendortype-oid .mib ENTITY-MIB Removing "A" from 7500 entPhysicalModel Name hh3c-entity-vendortype-oid .
HP 7500-CMW520-R6701 Release Notes • Workarounds: ○ Before upgrading to the new code, it is necessary to ensure password control is disabled. Execute the “undo password-control enable” and then save this configuration file as a backup in case you need to downgrade the software again. If it is later necessary to downgrade to earlier software, force the switch to use this backup configuration file by executing a ”startup saved-configuration (filename)” command before rebooting to the old code.
HP 7500-CMW520-R6701 Release Notes • Description: BGP fails to learn a private summary route received from a BGP peer because the route does not carry the RT attribute. • Workaround: Do not configure BGP route summarization for private networks. LSD59694 • First found-in version: CMW520-R6626 • Description: The calculated Q-Bridge MIB port list is incorrect.
HP 7500-CMW520-R6701 Release Notes • Description: The switch may reboot abnormally. LSD68974 • First found-in version: CMW520- R6616 • Condition: An IRF system with SRPD fabric on 7506/7503 chassis. • Description: The cross-chassis forwarding packets will be lost. Resolved problems in R6635 LSD66053 • First found-in version: CMW520-R6626 • Description: When Portal is enable and HTTP attack occurs, the memory leaks. • Workaround: None.
HP 7500-CMW520-R6701 Release Notes Resolved problems in F6632 LSD64002 • First found-in version: CMW520-F6630 • Description: When voice-vlan is enabled, the oui-mac learned from the slave board can’t be synchronized to the master board. • Workaround: None. LSD64635 • First found-in version: CMW520-F6630 • Description: VRRP conflicts when it receives a wrong SIP ARP request. • Workaround: None.
HP 7500-CMW520-R6701 Release Notes • Description: RRPP fails to operate when the RRPP control VLAN ID is identical with the sub interface VLAN ID. • Workaround: Do not configure the same VLAN ID for them. LSD62435 • First found-in version: CMW520-R6616P05 • Description: A sub interface fails to forward traffic to another chassis when its VLAN ID is identical with the MAD VLAN ID. • Workaround: Do not configure the same VLAN ID for them.
HP 7500-CMW520-R6701 Release Notes • Description: EA board can not transmit OSPF hello packets, and cause that other devices can not build OSPF neighbors across EA boards. LSD58787 • First found-in version: CMW520-E6612 • Description: More CF card types are supported CMW520-F6618L08. Resolved problems in R6616P02 LSD55210 • First found-in version: CMW520-R6616P01 • Description: Sometimes IP packets will fail to be forwarded after configured the IP FRR function.
HP 7500-CMW520-R6701 Release Notes • Description: Voice VLAN does not support enough OUI MAC addresses. (In CMW520-R6616, voice VLAN supports 128 OUI MAC addresses) LSD49124 • First found-in version: CMW520-E6612 • Description: The MA/MD naming format does not support enough special characters. (In CMW520-R6616, the MA/MD naming format supports more special characters.
HP 7500-CMW520-R6701 Release Notes System software images System software images are used at switch startup. The 7500 series support two types of system software image: • Main system software image: The default system software image a switch uses for startup. • Backup system software image: The system software image a switch uses for startup when the main system software image is invalid. Normally, an .app file such as 7500.
HP 7500-CMW520-R6701 Release Notes Upgrade from the CLI The upgrade procedure on a standalone switch is different from that on an Intelligent Resilient Framework (IRF) fabric. This section describes the following topics: • Upgrading a standalone switch • Upgrading an IRF fabric NOTE: Up to two 7500 series switches can form a distributed IRF fabric. One switch is the master, and the other is the slave.
HP 7500-CMW520-R6701 Release Notes 1 -rw- 6625 Jun 02 2010 16:50:51 switch.cfg 2 -rw- 27475851 Aug 11 2010 11:04:20 switch001.app 3 -rw- 31782388 Jul 23 2010 09:25:21 switch002.app 64389 KB total (5636 KB free) Check that the free storage space is sufficient for the new .app file. You can delete undesired files with the delete command to free storage space. # Delete undesired files from the active and standby MPUs. • On the active MPU delete /unreserved flash:/switch001.
HP 7500-CMW520-R6701 Release Notes 230 User logged in # Set the file transfer mode to binary. [ftp] binary 200 Type set to I. # Download the .app file from the PC to the root directory of the storage medium on the active MPU. [ftp] get newest.app 227 Entering Passive Mode (10,10,110,1,17,97). 125 BINARY mode data connection already open, transfer starting for /newest.app 226 Transfer complete. FTP: 28945856 byte(s) received in 35.974 second(s), 896.00K byte(s)/sec. [ftp] bye 221 Server closing. 3.
HP 7500-CMW520-R6701 Release Notes Bootrom update succeeded in slot 0. # Upgrade the Boot ROM for the standby MPU in slot 1. bootrom update file slot1#flash:/newest.app slot 1 This command will update bootrom file on the specified board(s), Continue? [Y/N]:y Now updating bootrom, please wait... Start accessing bootflash chip... Bootrom update succeeded in slot 1. # Upgrade the Boot ROM for the LPU in slot 3. bootrom update file flash:/newest.
HP 7500-CMW520-R6701 Release Notes This command will set the boot file of the specified board. Continue? [Y/N]:y The specified file will be used as the main boot file at the next reboot on slot 1! # Reboot the switch to validate the upgrade. reboot Start to check configuration with next startup configuration file, please wait. ........DONE! This command will reboot the device.
HP 7500-CMW520-R6701 Release Notes display device Chassis Slot Type State Subslot Soft Ver Patch Ver 1 0 LSQ1SRP1CB Master 0 7500 None 1 1 LSQ1SRP1CB Slave 0 7500 None 1 2 LSQ1TGX4SD Normal 0 7500 None 1 3 LSQ1TGX4SD Normal 0 7500 None 1 4 LSQ1TGX4SD Normal 0 7500 None 2 0 LSQ1SRP1CB Slave 0 7500 None 2 1 LSQ1SRP1CB Slave 0 7500 None 2 2 LSQ1TGX4SD Normal 0 7500 None 2 3 LSQ1TGX4SD Normal 0 7500 None 2 4 LSQ1TGX4SD Normal 0
HP 7500-CMW520-R6701 Release Notes 2 -rw- 27475851 Aug 11 2010 11:04:20 switch002.app 64389 KB total (31788 KB free) On the standby MPU in slot 1 of member device 2 • dir chassis2#slot1#flash:/ Directory of chassis2#slot1#flash:/ 0 -rw- 3597 Sep 01 2009 18:35:28 startup.cfg 1 2 -rw- 6625 Jun 02 2010 16:50:51 switch.cfg -rw- 27475851 Aug 11 2010 11:04:20 switch002.
HP 7500-CMW520-R6701 Release Notes Trying ... Press CTRL+K to abort Connected to 10.10.110.1 220 3Com 3CDaemon FTP Server Version 2.0 User(10.10.110.1:(none)):username ---Type the username. 331 User name ok, need password Password: ---Enter the password. 230 User logged in # Set the file transfer mode to binary. [ftp] binary 200 Type set to I. # Download the .app file from the PC to the root directory of the storage medium on the active MPU of the IRF fabric. [ftp] get newest.
HP 7500-CMW520-R6701 Release Notes NOTE: Make sure that the upgrade files exist in the root directory of the storage medium of the active and standby MPUs of the IRF fabric. Perform the following tasks as needed: • Upgrade Boot ROM • Upgrade system software • Install patches 1. Upgrade Boot ROM # Upgrade the Boot ROM program of the active MPU of the IRF fabric. bootrom update file flash:/newest.
HP 7500-CMW520-R6701 Release Notes NOTE: • You cannot upgrade the Boot ROM program of the LPUs on the member switches of an IRF fabric. • The Boot ROM image stored on the active MPU of the IRF fabric can be used to upgrade the active MPU and LPUs of the IRF fabric, while that stored on a standby MPU of the IRF fabric can be used to upgrade the standby MPU only. 2. Upgrade system software # Specify the file newest.
HP 7500-CMW520-R6701 Release Notes # Download the patch files to the root directory of the storage medium of the active and standby MPUs, and then install the patch files with the patch install command. system-view [Sysname] patch install flash: Patches will be installed. Continue? [Y/N]:y Do you want to continue running patches after reboot? [Y/N]:y Installing patches........ Installation completed, and patches will continue to run after reboot. NOTE: • A patch file must have a valid name.
HP 7500-CMW520-R6701 Release Notes Memory Type : DDR SDRAM Memory Size : 512MB Memory Speed : 133MHz BootRom Size : 512KB Flash Size : 64MB CPLD Version : 006 PCB Version : Ver.B Mac Address : 0023895F954F Press Ctrl+B to enter Boot Menu...2 NOTE: • To enter the boot menu, press Ctrl+B within 5 seconds when you see "Press Ctrl+B to enter Boot Menu..." If you failed to do so, restart the switch and try again. • The output varies with switch models. Press Ctrl+B.
HP 7500-CMW520-R6701 Release Notes Step2 Run the TFTP server program on the PC connected to the management Ethernet port and specify the file storage directory. Step3 Run the terminal emulation program on the PC connected to the console port. Start the switch, enter the boot menu (see Boot menu for more information), and press Ctrl+U when you see "Enter your choice(0-5):" to enter the Boot ROM update menu. BootRom update menu: 1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3.
HP 7500-CMW520-R6701 Release Notes 1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3. Set XMODEM protocol parameters 4. Update through file in device 0. Return to boot menu Enter your choice(0-4): Step8 Type 0 to return to the boot menu. BOOT MENU 1: Download application file to device 2: Select application file to boot 3: Display all files in device 4: Delete file from device 5: Modify bootrom password 0: Reboot Enter your choice(0-5):0 Step9 Type 0 to reboot the switch.
HP 7500-CMW520-R6701 Release Notes 2. Set FTP protocol parameters 3. Set XMODEM protocol parameters 4. Update through file in device 0. Return to boot menu Enter your choice(0-4):2 Load File name :newest.app The name of the target .app file Switch IP address :10.10.10.2 The IP address of the switch Server IP address :10.10.10.3 The IP address of the PC that stores the .
HP 7500-CMW520-R6701 Release Notes 0: Reboot Enter your choice(0-5):0 Step9 Type 0 to reboot the switch. NOTE: The Boot ROM upgrade takes effect at the next startup. Using Xmodem through the console port Step1 Connect the console port of the switch to the PC that stores the upgrade files. Step2 Run the terminal emulation program on the PC.
HP 7500-CMW520-R6701 Release Notes NOTE: If you want to use the baud rate of 9600 bps, select it and directly go to Step 7. In this case, the system does not display the above information. Step5 Disconnect HyperTerminal from the switch by clicking Disconnect in the HyperTerminal window. Step6 Select File > Properties in the HyperTerminal window, click Configure in the popup dialog box, and select the baud rate of 19200 bps in the console port properties dialog box.
HP 7500-CMW520-R6701 Release Notes Figure 2 The console port properties dialog box Step7 Click Connect to re-connect to the switch. The following information appears: Now please start transfer file with XMODEM protocol. If you want to exit, Press Downloading ...CCCCCCCCCCCCCCC Step8 Select Transfer > Send File in the HyperTerminal window. In the Send File dialog box that appears, click Browse to select the target .app file, and select Xmodem as the protocol.
HP 7500-CMW520-R6701 Release Notes Figure 4 The Xmodem file send for Switch dialog box Step10 When the file is successfully downloaded, the following information appears: Loading...........done! Will you Update Basic BootRom? (Y/N): Step11 Answer Y to the question. The following information appears: Will you Update Basic BootRom? (Y/N):Y Updating Basic BootRom..........done! Updating extended BootRom? (Y/N): Step12 Answer Y to the question.
HP 7500-CMW520-R6701 Release Notes 4: Delete file from device 5: Modify bootrom password 0: Reboot Enter your choice(0-5):0 Step14 Type 0 to reboot the switch. NOTE: After the reboot, you must change the baud rate for HyperTerminal back to 9600 bps by following Step 5 and Step 6. Using an upgrade file on the switch Step1 Connect the console port of the switch to a PC. Step2 Run the terminal emulation program on the PC.
HP 7500-CMW520-R6701 Release Notes Step5 Answer Y to the question. The following information appears: Load file from flash to sdram......done! The file you selected is not the primary boot file, are you sure you want to update from it? Yes or No(Y/N)Y Step6 Answer Y to the question. The following information appears: Will you Update Basic BootRom? (Y/N): Step7 Answer Y to the question. The following information appears: Updating Basic BootRom..........
HP 7500-CMW520-R6701 Release Notes NOTE: Skip this section if the new system software image already exists on your switch. 1. Using TFTP through the management Ethernet port Step1 Connect the management Ethernet port of the switch to the PC that stores the target .app file (the IP address of the PC is required), and connect the console port of the switch to the same or another PC.
HP 7500-CMW520-R6701 Release Notes Free space: 37584896 bytes Writing flash.................................................................. ............................................................................... ..........................done! The attribute of old.app is changed from main to none! done! 1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3. Set XMODEM protocol parameters 0. Return to boot menu Enter your choice(0-3): 0 Step7 Type 0 to return to the boot menu.
HP 7500-CMW520-R6701 Release Notes Switch IP address :10.10.10.2 The IP address of the switch Server IP address :10.10.10.3 The IP address of the PC that stores the .app file FTP User Name FTP User Password :username :12345 The FTP username. The password. NOTE: The switch must be on the same network segment as the PC storing the upgrade files. Step12 Set the FTP parameters and press Enter.
HP 7500-CMW520-R6701 Release Notes 0. Reboot Enter your choice(0-5):1 Step17 In the download protocol menu, type 3. The switch asks you to provide the name of the file you want to download. 1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3. Set XMODEM protocol parameters 0. Return to boot menu Enter your choice(0-3): 3 Load File name :update.app The name of the file to be downloaded Step18 Type the file name and the download baud rate menu appears.
HP 7500-CMW520-R6701 Release Notes Figure 5 Switch Properties dialog box Hewlett-Packard Development Company, L.P.
HP 7500-CMW520-R6701 Release Notes Figure 6 Console port properties dialog box Step8 Click Connect to re-connect to the switch. The following information appears: Now please start transfer file with XMODEM protocol. If you want to exit, Press Downloading ...CCCCCCCCCCCCCCC Step9 Select Transfer > Send File in the HyperTerminal window. In the Send File dialog box that appears, click Browse to select the target .app file, and select Xmodem as the protocol.
HP 7500-CMW520-R6701 Release Notes Figure 8 The Xmodem file send for Switch dialog box Step11 When the file is successfully downloaded, the following information appears: Loading ...CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC.done! Free flash Space : 65932288 bytes Writing flash....
HP 7500-CMW520-R6701 Release Notes Set new main and backup system software images After you download a new system software image to the switch, set the file as the main or backup system software image. The switch uses the main system software image in normal cases, and uses the backup system software image when the main system software image is invalid. Follow these steps to set the new main and backup system software images: Step1 In the boot menu, type 2 to enter the system software image menu.
HP 7500-CMW520-R6701 Release Notes Starting to get the main application file--flash:/ newest.app!.. ............................................................................... ............................................................................... The main application file is self-decompressing................................ ............................................................................... ......................................................................