HP 7500 Switch Series - HP 7500-CMW520-R6701 Release Notes

HP 7500-CMW520-R6701 Release Notes
Hewlett-Packard Development Company, L.P. 20
Description: The switch may reboot abnormally.
LSD68974
First found-in version: CMW520- R6616
Condition: An IRF system with SRPD fabric on 7506/7503 chassis.
Description: The cross-chassis forwarding packets will be lost.
Resolved problems in R6635
LSD66053
First found-in version: CMW520-R6626
Description: When Portal is enable and HTTP attack occurs, the memory leaks.
Workaround: None.
LSD66086
First found-in version: CMW520-R6626
Description: If command display diagnosis or save diagnosis runs on slave-super-engine, it can’t
return.
Workaround: Run this command on master-super-engine.
LSD64527
First found-in version: CMW520-R6626
Description: When the device is linked with other companys device with VLL, the LDP session is not
stable.
Workaround: None.
LSD62656
First found-in version: CMW520-R6626
Description: When the is highly occupied, BGP neighbors are not stable.
Workaround: None.
LSD63920
First found-in version: CMW520-R6626
Description: When the LLDP packets whose LCI value in location ID TLV is zero enter the device, the
LLDP neighbor’s information is wrong.
Workaround: None.
LSD66072
First found-in version: CMW520-R6626
Description: Non-compatible transceiver module will be invalidated in 30 days.
Workaround: Use compatible transceiver module.