HP FlexFabric 11900 Switch Series - HP 11900-CMW710-R2105P05 Release Notes
Upgrade method
Software type
Remarks
Upgrading from the CLI
without using ISSU
• BootWare
• Comware images
(excluding
patches)
This method is disruptive. If you are upgrading MPUs, you
must reboot the switch to complete the upgrade. If you are
upgrading the BootWare of a card (an LPU or switching
fabric module), you must reboot the card.
NOTE:
You can upgrade the BootWare of LPUs and switching
fabric modules from the CLI only.
Upgrading from
BootWare menus:
• Upgrading Comware
software from the
BootWare menu
• Upgrading BootWare
from the BootWare
menu
• BootWare
• Comware images
Use this method when the device cannot start up correctly.
Performing an ISSU
• Comware images
• Patches
ISSU enables a software upgrade without service
interruption.
Patches repair software defects and do not add new
features to Comware software.
This chapter covers only installing patches. For
information about using ISSU to upgrade Comware
images, see Fundamentals Configuration Guide in HP
11900 Switch Series Configuration Guides.
NOTE:
•
Use the same method to upgrade software for all MPUs
to ensure software version consistency across
MPUs.
•
Make sure the Comware software and BootWare are compatible. For the compatibility between the
Comware software and BootWare, see the hardware and software compatibility matrix in the
Release
Notes.
• The command outputs in this document are for reference only.
Upgrading from the CLI without using ISSU
This section describes the upgrade procedures for standalone HP 1190 0 switches and 11900 IRF fabrics.
For more information about IRF, see HP 119 0 0 Switch Series IRF Configuration Guide.
Upgrading a standalone switch
Preparing for the upgrade
1. Telnet to the switch or log in through the console port. (Details not shown.)
2. Display device information.
<Sysname> display device
Slot No. Type Status Subslot Soft Ver Patch Ver
0 NONE Absent 0 NONE None
1 NONE Absent 0 NONE None