HP FlexFabric 12900 Switch Series - 12900_7.1.R1106-B_Release-Notes-Portfolio
3
5 NONE Absent 0 NONE None
6 NONE Absent 0 NONE None
7 NONE Absent 0 NONE None
8 NONE Absent 0 NONE None
9 LSX1TGS48FC1 Normal 0 12900-1106 None
10 LSX1FAB10B1 Normal 0 12900-1106 None
11 LSX1FAB10B1 Normal 0 12900-1106 None
12 NONE Absent 0 NONE None
13 NONE Absent 0 NONE None
14 NONE Absent 0 NONE None
15 NONE Absent 0 NONE None
16 LSX1SUP10A1 Standby 0 12900-1106 None
17 LSX1SUP10A1 Master 0 12900-1106 None
The output shows that the switch has two MPUs, an active MPU in slot 17 and a standby MPU in
slot 16. You must upgrade software for the two MPUs.
NOTE:
You only need to upgrade the active MPU if the device has no standby MPU.
3. Verify that the MPUs have enough free storage space for the upgrade files:
# On the active MPU:
<Sysname> dir
Directory of flash:
0 drw- - Aug 06 2013 17:26:38 diagfile
1 -rw- 42 Aug 07 2013 08:55:30 ifindex.dat
2 drw- - Aug 06 2013 17:26:38 license
3 drw- - Aug 06 2013 18:26:41 logfile
4 -rw- 102294528 Apr 07 2013 13:47:21 12900-CMW710-R1106.ipe
5 -rw- 14908416 Aug 06 2013 17:21:31 12900-cmw710-boot-r1106.bin
6 -rw- 110083072 Aug 06 2013 17:23:20 12900-cmw710-system-r1106.bin
7 drw- - Aug 06 2013 17:26:38 seclog
8 -rw- 1982 Aug 07 2013 08:55:30 startup.cfg
9 -rw- 33368 Aug 07 2013 08:55:31 startup.mdb
10 drw- - Aug 06 2013 17:26:40 versionInfo
1028096 KB total (487680 KB free)
# On the standby MPU:
<Sysname> dir slot16#flash:
Directory of slot16#flash:
0 drw- - Aug 06 2013 17:26:38 diagfile
1 -rw- 42 Aug 07 2013 08:55:30 ifindex.dat
2 drw- - Aug 06 2013 17:26:38 license
3 drw- - Aug 06 2013 18:26:41 logfile
4 -rw- 102294528 Apr 07 2013 13:47:21 12900-CMW710-R1106.ipe
5 -rw- 14908416 Aug 06 2013 17:21:31 12900-cmw710-boot-r1106.bin
6 -rw- 110083072 Aug 06 2013 17:23:20 12900-cmw710-system-r1106.bin
7 drw- - Aug 06 2013 17:26:38 seclog
8 -rw- 1982 Aug 07 2013 08:55:30 startup.cfg