Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Table of Contents 1 Version Information....................................................................................................................... 5 1.1 Version Number .................................................................................................................... 5 1.2 Chronological List of Version ................................................................................................
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes List of Tables Table 1 Version Information Table ............................................................................................ 5 Table 2 Version Compatibility Table.......................................................................................... 5 Table 3 Changed Features...................................................................................................... 15 Table 4 Changes in Commands....
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 1 Version Information 1.1 Version Number Version Information: Comware Software, Version 5.20, Release 6305P02 Note: This version number can be displayed by command display version under any view. Please see Note①. 1.
H3C S7500E-CMW520-R6305P02 Release Notes Hangzhou H3C Technologies Co., Ltd. Hardware Platform S7500E Series Ethernet switches iMC ACLM 3.20-E2601 iMC EAD 3.60-E6101 iMC EPM 3.50-E5101 iMC Version iMC iCC 3.20-E2601 iMC MVM 3.50-E5101 iMC PLAT 3.20-E2601 iMC UAM 3.60-E6101 iNode Version WX6103 Series WLAN iNode 3.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes SRPG(S) 1: Uptime is 0 weeks,2 days,0 hours,23 minutes S7506E SRPG(S) with 1 BCM1125H Processor DRAM: 512M bytes FLASH: 64M bytes NVRAM: 512K bytes PCB 1 Version: VER.B PCB 2 Version: VER.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 1. Enable the non-standard PD checking of POE on port, if connected to the device not support PD checking, such as PC, the checking status of the port is wrong. 2. Not support subnet-based vlan by port. 3. The protocol-based vlan does not support AppleTalk protocol. 4. Vlan-based Qos is invalid on QinQ port. 5. EA series boards don’t support Portal. 3 Version Features 3.
Hangzhou H3C Technologies Co., Ltd.
Hangzhou H3C Technologies Co., Ltd.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 3.2 Version Software Features Feature Description Ethernet II IEEE 802.3/802.2 SNAP IEEE 802.3/802.2 Long Frame(1518-1536) Jumbo Frame(1536-9216) Vlan (Port-based vlan/Subnet-based vlan/Mac-based Vlan) vlan/Protocol-based IEEE 802.1Q IEEE802.1p Layer 2 RSTP(802.1w) MSTP(802.1s) LACP(802.
Hangzhou H3C Technologies Co., Ltd.
H3C S7500E-CMW520-R6305P02 Release Notes Hangzhou H3C Technologies Co., Ltd. Feature Description IGMP Snooping IGMP MLD Snooping MLD Multicast PIM-DM PIM-SM MSDP remark 802.1p, DSCP, IP precedence, local precedence by ACL rule map to output queue by 802.
Hangzhou H3C Technologies Co., Ltd.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 4 Version Changes 4.1 Changed Features Table 3 Changed Features Version Number Item Changed Hardware Features S7500ECMW520R6305P02 Description New features: None New boards: None Deleted features: None New features: None Changed Software Features Deleted features: None Modified features: None 4.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 4.4 Changes in Operations None 5 Unresolved Problems and Avoidance Measures 1. LSD13634 First Found-in Version: CMW520-E6301 Description: configure QOS and broadcast suppression in the same port, the broadcast is not accurate Avoidance: avoid configure QOS and broadcast suppression in the same port simultaneously 2.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Description: The flow-mirror can not be applied to the double-tag packets. Avoidance: use port based mirror 6. TCD00800 First Found-in Version: CMW520-E6301 Description: MSTP network's constringency time may reach 20 second in some topology Avoidance: none 7. LSD22212 First Found-in Version: CMW520-E6301 Description: ARP can not fresh by mac address in the double switch-chip board Avoidance: none 8.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Avoidance: reconfigure it will resolve the problem. 12. LSD29832 First Found-in Version: CMW520-E6301 Description: The ntp multicast-client configuration on vlan interface can’t restore after reboot. Avoidance: reconfigure it will resolve the problem. 13. LSD29776 First Found-in Version: CMW520-E6301 Description: The port-based dot1x on EPON ONU port, the authentication time is very long.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Description: The next-hop of CCC is point to a virtual-IP for virtual-mac VRRP, the VPN can’t works. Avoidance: Please avoid MPLS and VRRP work together. 18. LSD33732 First Found-in Version: CMW520-E6301 Description: With 1CB fabric + SC line cards under l2-enhanced swith-mode, if the route nesting with FTN route, the MPLS can’t work normally. Avoidance: Please use standard-routing switch-mod. 19.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 4. LSD29883 First Found-in Version: CMW520-E6301 Description: If customer configured the a lot of NQA sessions, it will cause the CPU to 100%. 5. LSD29028 First Found-in Version: CMW520-E6301 Description: Resolve the Network Manager DM can’t display the first port on the Fabric. 6. LSD29156 First Found-in Version: CMW520-E6301 Description: Modify the MIB Item sysDescr based on the criterion. 7.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Description: Under l2-enhanced mode,there are some problems about the mac address learning on link aggregation port on SA modules. It will cause the L2 forwarding blocking for a while if there are the attacked stream. Improve the synchronization for SRPB/SRPD/1CB modules. 12.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Table 7 Online technical support How to apply for an account Access the homepage of H3C at http:// www.h3c.com and click on Registration at the top right. In the displayed page, provide your information and click on Submit to register. Approach 1: How to get documentation In the homepage of H3C at http:// www.h3c.com, select Technical Support & Document > Technical Documents from the navigation menu at the top.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 8.1 Remote Upgrading through CLI You may upgrade the application and Boot ROM program of a device remotely through command line interface (CLI). Firstly, telnet to the device from a computer (at 10.10.110.1) running FTP Server first; and then FTP the application program, S7500.app. for example, from the FTP server as follows: ftp 10.10.110.1 Trying 10.10.110.1 ... Connected to 10.10.110.1. 220 WFTPD 2.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes The following introduces the general methods that service personal uses for local upgrading. 8.2 Boot Menu After power on, H3C S7500E series LAN Switch runs BOOTROM at first. The terminal displays as follows (The following takes S7500E Switch as an example): Starting...... RAMLine.....OK System is booting................
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Press Ctrl+B to enter Boot Menu... 5 password: Press , system enters BOOT menu. Note: Press in the five seconds to enter BOOT menu when system displays "Press Ctrl-B to enter Boot Menu...". Or system runs program decompression procedure. After that you need to restart the switch to enter BOOT menu. The system prompts: Password : Enter the Boot ROM password.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Please set application file download protocol parameter: 1. Set TFTP protocol parameter 2. Set FTP protocol parameter 3. Set XMODEM protocol parameter 0. Return Enter your choice(0-3):3 Step 2: Enter 3 in the download program menu. Select to implement the software upgrading via Xmodem protocol. Press and the screen will display the following information: Please select your download baudrate: 1. 9600 2. 19200 3. 38400 4.
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes Step 5: Select [Transfer\Send File] from the terminal window. Click in the pop-up window and select the software to be downloaded. Change the protocol name to Xmodem. Step 6: Click button. Step 7: After the downloading of the program is completed, the screen will display the following information: Loading ........................................................done Writing to flash................................
Hangzhou H3C Technologies Co., Ltd. H3C S7500E-CMW520-R6305P02 Release Notes 3. Set XMODEM protocol parameter 0. Return Enter your choice(0-3):1 Step 5: Enter 1 in the download program menu. Select to use TFTP for the software upgrading. Press and the screen will display the following information: Please modify your TFTP protocol parameter: Load File name Switch IP address Server IP address Step 6: Complete the relevant information based on the actual requirements and press .