Please set application file download protocol parameter:
1. Set TFTP protocol parameter
2. Set FTP protocol parameter
3. Set XMODEM protocol parameter
0. Return
Enter your choice(0-3):3
Step 2: Enter 3 in the download program menu. Select to implement the software
upgrading via Xmodem protocol. Press <Enter> and the screen will display the
following information:
Please select your download baudrate:
1. 9600
2. 19200
3. 38400
4. 57600
5. 115200
6. Exit
Enter your choice (0-5):
Step 3: Select the appropriate download speed based on the actual requirements. For
example, enter 5 to select the download speed as 115200bps. Press <Enter> and the
system will display the following information:
Download baudrate is 115200 bps. Please change the terminal's baudrate to
115200 bps, and select XMODEM protocol.
Press ENTER key when ready.
Step 4: Follow the above prompt and change the baud rate on the console terminal,
so that the baud rate is consistent with the selected download baud rate of the
software. After the baud rate setting at the console terminal is completed, disconnect
the terminal and reconnect it. Press <Enter> to start downloading, and the screen will
display the following information:
Are you sure to download file to flash? Yes or No(Y/N)y
Now please start transfer file with XMODEM protocol.
If you want to exit, Press <Ctrl+X>.
Downloading ... CCCCC
Note:
After the terminal baud rate is modified, it is necessary to disconnect and then re-