Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Table of Contents 1 Version Information .............................................................................................................. 5 1.1 Version Number ........................................................................................................... 5 1.2 Chronological List of Version ......................................................................................... 5 1.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes List of Tables Table 1 Version Information Table......................................................................................5 Table 2 Version Compatibility Table ...................................................................................5 Table 5 Changed Feat ures ..............................................................................................10 Table 6 Changes in Commands ..........................
H3C S7500-CMW310-R3234P03 Release Notes Hangzhou H3C Technologies Co., Ltd. 1 Version Information 1.1 Version Number Version Information: Comware(R) soft ware, Version 3.10, Releas e 3234P03 Note: This version number can be displayed by command di splay version under any view. Please see Note①. 1.2 Chronological List of Version Table 1 Version Information Table Version Number Based Version Number Release Date Remark CMW310-R3234P 03 R3234P 02 2011-08-15 None.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Memory Requirement Min 256M Flash Requirement Min 32M SRPG: Uses the version shipped with the device, and no need to update Boot ROM Version LPU boards require Boot ROM 537 or lat er (Note: This version number can be display ed by command display version under any view. Please see Note② ) Host Software S7500-CMW310-F3234P03.app iMC EAD 5.0 SP1 (E0101P03) iMC Version iMC PLAT 5.0 SP1 (E0101L07) iMC UAM 5.
H3C S7500-CMW310-R3234P03 Release Notes Hangzhou H3C Technologies Co., Ltd. BootROM Version : 537 CPLD Version : 001 Software Version : Patch Version S7503-3234P03 : None 2 Version Usage Limitations and Important Notes This edition software version need to be notice in the usage as follows items and the usage restrict. The command “fixdisk” can not used to CF card When POE power down, please keep at least 5 seconds to power up again. 3 Version Features 3.
Hangzhou H3C Technologies Co., Ltd.
Hangzhou H3C Technologies Co., Ltd. Operation environment humidity H3C S7500-CMW310-R3234P03 Release Notes 5%-85% 3.2 Version Software Features Table 4 Software Features Item Description Supports 4K VLAN, GVRP Supports VLAN Trunk Supports GMRP ,IGMP, PIM DM, PIM SM Supports STP/RS TP/MS TP and MA C address management Supports link aggregation that consists of up to 16 Fast Ethernet (FE) ports or 8 GE ports Supports broadcast storm suppression Supports 802.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Management and maintenance: Supports command line configuration Supports Telnet remote configuration Supports dialing remote configuration through MODEM Supports SNMPV3 Support system log Management and maintenance Supports user level alarm Supports debugging information out put Supports PING and Trac ert Upgrade: Supports upgrade via XModem protocol Supports upgrade via FTP Supports upgrade via TFTP 4 Version Changes 4.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Version Number Item Description Modified Commands None. 4.3 Changes in MIBs Table 7 Changes in MIB Files Version Number S7500CMW310R3234P03 Item MIB File Name New None. Modified None. Modified None. Module Name Description 4.4 Changes in Operations 4.4.1 CMW310- R3234P03version Changes in Operations None. 5 Unresolved Problems and Avoidance Measures 1.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes A voidance: None. 3. OPTED05717 First Found-in Version: CMW310-E 3203 Description: RPR SoC has a bug with backpressure signal. A voidance: None. 4. OPTED04847 First Found-in Version: CMW310-E 3203 Description: It has no limit with the number of security-VLAN by command-line, but the firewall blade supports up to 128. A voidance: Please do not configure over 128 security-VLANs. 5.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes 2. LSOD10093 First Found-in Version: CMW310-R3234 Condition: Configure clock summer-time Description: System Exception occurred, system reboot. 3. LSOD10021 First Found-in Version: CMW310-R3234 Condition: use the M-eth port in S6502 Description: The port does not access 6.3 Resolved Problems in VRP310-R3234P01 1. LSOD09878 First Found-in Version: CMW310-R3234 Condition: use those board which provides 10Ge Port .
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Description: after monit or port board restart, the local mirror configure is lost. 6.5 Resolved Problems in CMW310-F3233 1. LSOD09086 First Found-in Version: CMW310-R3135P15 Condition: Insert GE -T type SFP modules in GP48 line card, and configure speed and duplex parameters for them. Description: speed and duplex configuration loss when system rebooting. 6.6 Resolved Problems in CMW310-F3232 1.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes 2. LSOD08933 First Found-in Version: CMW310-R3135P15 Condition: S7500 open super VLAN and DHCP relay features on same VLAN interface. Description: users get ip address and re-lease ip address too slowly in sub VLAN. 3. LSOD08737 First Found-in Version: CMW310-R3135P18 Condition: S7500 running DHCP snooping or DHCP relay function. DHCP server send offer packet with option82 doing not be placed on packet tail.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Description: If the peer device does not follow standard sending LA CP packet large than 128 bytes, S75 drop it. Change should be taken for cooperation. 2. LSOD07605 First Found-in Version: CMW310-E3228 Condition: apply rules on ten GE line card. Description: can not apply above 256 rules. But ten-GE port can apply up to 1K rules. 6.9 Resolved Problems in CMW310-E3229 1.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes 6.10 Resolved Problems in CMW310-E3226 1. LSOD03861 First Found-in Version: CMW310-E 3225 Condition: When working in manual mode, enable voice VLAN on port first, then specify its voice VLAN id, voice traffic cannot be remark priority by switch. It has no problem when working in auto mode. Description: Voice traffic cannot be remark priority. 2.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Manual H3C S7500 Series Install Manual Version (V1.02) 7.2 Online Technical Support To query and download the documentation for this version, go to the website of H3C with reference of the following Table. Table 9 Online technical support How to apply for an account Access the homepage of H3C at http:// www.h3c.com and click on Registration at the top right.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Use TFTP protocol to upgrade through the Ethernet interface of the routing switch unit; Use FTP protocol to upgrade through the Ethernet interface of the routing switch unit; Use XMODEM protocol to upgrade through the Console port of the routing switch unit. Using Ethernet interfac e, the first two ways come in faster download. Setting user name and password is necessary for FTP, so dos not TFTP.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes restart) Now you complete the host software and BootRom upgrade (The reboot command is necessary to restart the switch). Note: In case of inadequate Flash memory, you can delete some of the program files in Flash, some host program that is no longer in use for example, after completing Bootrom upgrading. Then FTP the host program to the switch for upgrading. Power off is prohibited in the process of upgrading..
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Press Ctrl+B to enter Boot Menu... 5 Press , system enters BOOT menu. Note: Press in the five seconds to enter BOOT menu when system displays "Press Ctrl-B to ent er Boot Menu...". Or system runs p rogram decompression procedure. After that you need to restart the switch to enter BOOT menu. The system prompts: Password : Enter the B oot ROM password.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Step 2: Enter 3 in the download program menu. Select to implement the software upgrading via Xmodem protocol. Press and the screen will display the following information: Please select your download baudrate: 1. 9600 2. 19200 3. 38400 4. 57600 5. 115200 6. Exit Enter your choice (0-5): Step 3: Select the appropriat e download speed based on the actual requirement s.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Loading ........................................................done Writing to flash................................................done 8.4 Software Upgrading via Ethernet Interface (FTP/TFTP) 1. Software Upgrading via TFTP 1) Introduction to TFTP TFTP (t rivial file transfer protocol) is a type of simple file transfer protocol in the TCP/IP protocol suite that applies between clients and servers.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Server IP address Step 6: Complete the relevant information based on the actual requirements and press . The screen will display the following information: Are you sure to download file to flash? Yes or No(Y/N) Step 7: Enter Y and the system starts downloading the file. Enter N and the system will ret urn t o Boot menu. Take entering Y as an example. Enter Y and press , the system begins downloading programs.
Hangzhou H3C Technologies Co., Ltd. H3C S7500-CMW310-R3234P03 Release Notes Switch IP address Server IP address FTP User Name FTP User Password Step 6: Complete the relevant information based on the actual requirement s and press . The screen will display the following information: Are you sure to download file to flash? Yes or No(Y/N): Step 7: Enter Y and the system starts downloading the file. Enter N and the system will return to Boot menu. Take the first case as an example.