Release Notes - H3C S7500E-CMW520-R6616P05

H3C S7500E-CMW520-R6616P05 Release Notes
26
the H3C S7500E Series Ethernet Switches Command Reference.
2. Install patches
# Download the patch files to the root directory of the storage medium of the active main board and that
of the standby main board, and then install the patch files with the patch install command.
<Sysname> system-view
[Sysname] patch install flash:
Patches will be installed. Continue? [Y/N]:y
Do you want to continue running patches after reboot? [Y/N]:y
Installing patches........
Installation completed, and patches will continue to run after reboot.
NOTE:
For more information about patch installation, see Fundamentals in the H3C S7500E Series Ethernet
Switches Configuration Guide.
Upgrading an IRF Virtual Device
Upgrade prerequisites
# Telnet to the switch or log in through the console port.
# Display device information.
<Sysname> display device
Chassis Slot Type State Subslot Soft Ver Patch Ver
1 0 LSQ1SRP1CB Master 0 S7500E None
1 1 LSQ1SRP1CB Slave 0 S7500E None
1 2 LSQ1GP48EB Normal 0 S7500E None
2 0 LSQ1SRP1CB Slave 0 S7500E None
2 1 LSQ1SRP1CB Slave 0 S7500E None
2 2 LSQ1GV48SA Normal 0 S7500E None
2 3 LSQ1NAT24SC Normal 0 S7500E None
The output shows that two switches form an IRF virtual device. The following table shows the main board
information.
Table 10 Main board information of the IRF virtual device
Main board
Member ID
Slot number
Active main board of the IRF virtual device
1
0
Standby main board of the IRF virtual device
1
1
Standby main board of the IRF virtual device
2
0
Standby main board of the IRF virtual device
2
1
# Check the free storage space of the active and standby main boards on the IRF virtual device.
On the active main board of the IRF virtual device
<Sysname> dir