Release notes - H3C S9500-CMW310-R1652P03
Hangzhou H3C Technologies Co., Ltd.
H3C S9500-CMW310-R1652P03
Release Notes
2010-9-27 Page 34 of 56
When the next-hop of the route to CE changes, it will cause that remote device
cannot ping this CE.
6.2 Resolved Problems in S9500-CMW310-R1652P02
1. HYII07778
First Found-in Version: S9500-CMW310-R1652
Condition:
The S9500 device learns many of OSPF routes in the OSPF network, such as 40K
OSPF routes.
Description:
Delete OSPF configuration and then re-configure, this will result in rebooting
exceptionally.
2. HYII07776
First Found-in Version: S9500-CMW310-R1652
Condition:
The S9500 device has establish OSPF neighbors with peer which configure network
large segment.
Description:
It will result in S9500 device rebooting exceptionally.
6.3 Resolved Problems in S9500-CMW310-R1652
1. HYII07731
First Found-in Version: S9500-CMW310-R1651P05
Condition:
This problem occurs when you display fiber-module information.
Description:
The TX Power of fiber-module information is wrong.