S9500 series routing switches software is originally upgraded through serial port.
However, this mode is slow and time-consuming, it needs to be on site, and only one
device at a time. To facilitate software upgrading, S9500 series routing switches
introduce FTP module to implement fast and flexible software upgrade and file
download. The version offers a simpler upgrade way. Users can upgrade a switch by
using command line and rebooting the switch. Please confirm the current version
number before upgrading.
8.1 Remote Upgrading
8.1.1 Download program files
There are two methods to download program files: use the switch as a FTP server or
client
1. Using the switch as a FTP Server
Please configure FTP Server, User and Authentication information in system view:
[H3C] ftp server enable
% Start FTP server
[H3C] local-user 9500
New local user added.
[H3C-luser-9500] service-type ftp
[H3C-luser-9500] service-type ftp ftp-directory flash:/
[H3C-luser-9500] password simple 9500
Updating the password file, please wait...
Assuming that the host program file for upgrade is S9500-CMW310-R1652P03-
SI.APP; BootROM program files for upgrade include LSBSRP1N01303.APP for MPU,
LSBLMCUA01304.APP for LPU and LSBLMCUF02303.APP for L3PLUS board
(including VPNB, NATB and NAMB). We need to login the switch through FTP from
the local computer and put the program files to the switch. FTP uses the IP address
of the VLAN interface of the switch:
C:\> ftp 192.168.0.1
Connected to 192.168.0.1.
220 FTP service ready.
User (192.168.0.1:(none)): 9500
331 Password required for 9500.